Pressures, Checking, Vehicles With RESTRICTOR And Reservoir, Internally Regulated A/C Compressor: Notes
Connect the A/C service station. Refer to A/C SERVICE STATION, CONNECTING .
Observe the test requirements. Refer to PRESSURES, CHECKING .
-- With the ignition switched off, check the pressures in the refrigerant circuit (using the A/C service station). Refer to Refer to REFRIGERANT CIRCUIT, CHECKING PRESSURE WITH SERVICE STATION .
The pressures with the ignition turned off meet the specifications.
-- Start the engine.
-- Bring the engine speed up to 2000 RPM.
-- Observe the pressure gauge of the A/C service station.
The switching pressures for the refrigerant circuit switches are vehicle-specific.
The connection with the valve for low-pressure switch or at the evaporator is only to be used on vehicles with no service connection on the low-pressure side and with an inaccessible connection on the A/C compressor or reservoir (measuring exactness). Only applies to specific vehicles. Refer to Refrigerant Circuit (vehicle-specific service information).