Coolant Shut-Off Valve -N82-, REMOVING AND INSTALLING: Installing

WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2024 Audi SQ5, 2024 Audi Q5 e, 2024 Audi Q5, 2023 Audi SQ5, and 2023 Audi Q5 e. However, it is still accessible from the selected car via links, so may be relevant.

Install in reverse order of removal. Note the following.

TIP

-- Check the rubber bushing -L- is seated correctly in the bracket -K-.

-- Drain and fill the coolant circuit. Refer to COOLANT, DRAINING AND FILLING - DMSA or COOLANT, ADDING AND COOLING SYSTEM, BLEEDING, HIGH-VOLTAGE SYSTEM COOLING CIRCUIT - DPVA or COOLANT, DRAINING AND FILLING - EA839 .

Tightening Specification

Component Tightening Specification
Coolant Shut-Off Valve -N82- on the bracket 8 Nm
Bracket for the Coolant Shut-Off Valve -N82- on the plenum chamber 8 Nm