Possible deviation from specified value during the pressure test (5 Of 9)
WARNING: This page is about a different car, the 2023 Audi SQ8, 2023 Audi RS Q8, and 2023 Audi Q8. However, it is still accessible from the selected car via links, so may be relevant.
| Possible deviation from specified value during the pressure test |
- The required cooling is reached next after some or a long running time the cooling output is no longer sufficient.
- The high pressure and low pressure are normal.
- After some time the high pressure raises above the specified value, the low pressure corresponds to the specified value or it falls under the specified value.
|
| Possible causes for the deviation from specified value and their solutions |
- Radiator for coolant, condenser is contaminated or the activation of the radiator fan is not OK.
-- Check the activation of the radiator fan and if necessary service. Use the Vehicle Diagnostic Tester
in the "Guided Fault Finding" function of the A/C system.-- Check the condenser and radiator for the condenser for contamination and if necessary clean. Refer to
Refrigerant Circuit
(vehicle-specific service information) and
[For engine(s) DWRB, DWNB] Radiator/Radiator Fan
or [For engine(s) DCBD] Radiator/Radiator Fan
.
- The activation of the A/C Compressor Regulator Valve -N280- is faulty.
-- Check the activation of the A/C Compressor Regulator Valve A/C Compressor Regulator Valve -N280- and the measured value of the Evaporator Vent Temperature Sensor -G263- and if necessary service. Use the Vehicle Diagnostic Tester
in the "Guided Fault Finding" function of the A/C system.
- Too much refrigerant in the refrigerant circuit
-- Extract refrigerant from the refrigerant circuit. Refer to REFRIGERANT CIRCUIT, DISCHARGING
.-- If the extracted refrigerant quantity is substantially greater (more than 100 g (3.5 oz)) than the specified capacity. (refer to
Technical Data
(vehicle-specific service information), there is too much refrigerant in the refrigerant circuit. Refill the refrigerant circuit with the correct quantity of R1234yf and repeat the test.
- A/C Compressor Regulator Valve -N280- or A/C compressor is faulty
-- Check the function of the A/C Compressor Regulator Valve A/C Compressor Regulator Valve -N280- and if necessary remove the A/C Compressor Regulator Valve A/C Compressor Regulator Valve -N280- and if necessary check for contamination. Use the Vehicle Diagnostic Tester
in the "Guided Fault Finding" function of the A/C system and Refer to COMPONENTS, REPLACING
.-- Replace the A/C Compressor Regulator Valve A/C Compressor Regulator Valve -N280- or the A/C compressor. Refer to COMPONENTS, REPLACING
.-- If there is dirt in the refrigerant circuit clean the refrigerant circuit (flush with refrigerant R1234yf), expansion valve and desiccant bag/dryer cartridge (or replace the reservoir/receiver/dryer). Refer to COMPONENTS, REPLACING
and
Refrigerant Circuit
(vehicle-specific service information) and Refer to REFRIGERANT CIRCUIT, CLEANING
.
- Too much refrigerant oil in the refrigerant circuit
- Moisture in refrigerant circuit
-- Extract refrigerant from the refrigerant circuit. Refer to REFRIGERANT CIRCUIT, DISCHARGING
.-- If the extracted refrigerant quantity meets the specified capacity or is only slightly smaller (maximum 100 g (3.5 oz)) (refer to
Technical Data
(vehicle-specific service information) there too much refrigerant oil is in the refrigerant circuit.-- Clean the refrigerant circuit (flush with refrigerant R1234yf). Refer to REFRIGERANT CIRCUIT, CLEANING
.-- Replace the expansion valve and desiccant bag/dryer cartridge (or reservoir/receiver/dryer). Refer to COMPONENTS, REPLACING
and
Refrigerant Circuit
(vehicle-specific service information). |
| Final Procedures |
| -- Charge the refrigerant circuit. Refer to REFRIGERANT CIRCUIT, CHARGING .-- Repeat the test. Refer to MECHANICALLY DRIVEN A/C COMPRESSOR, CHECKING PRESSURE WITH A/C SYSTEM SWITCHED ON . |
NOTE:
If there is too much refrigerant oil in the circuit, the A/C compressor must be emptied and the desiccant bag (the dryer cartridge) or the receiver/receiver/dryer must be replaced. After cleaning (flushing with refrigerant R1234yf) (refer to REFRIGERANT CIRCUIT, CLEANING
) fill the refrigerant circuit with the correct quantity of refrigerant oil. Refer to
(vehicle-specific service information) and
Refrigerant Circuit
(vehicle-specific service information).
With this malfunction, evaporator may ice up although the quantity of refrigerant in circuit is OK.
A malfunction on the Evaporator Vent Temperature Sensor -G263- can also cause icing-up of refrigerant circuit. For this concern also pay attention to the measured value of the Evaporator Vent Temperature Sensor Evaporator Vent Temperature Sensor -G263-. Use the Vehicle Diagnostic Tester
in the "Guided Fault Finding" function of the A/C system and refer to
Component Location Overview - A/C System
(vehicle-specific service information).