Quick-Release Coupling Connections On Refrigerant Circuit: Notes
WARNING: This page is about a different car, the 2023 Audi SQ8, 2023 Audi RS Q8, and 2023 Audi Q8. However, it is still accessible from the selected car via links, so may be relevant.
- Only valves and connections that are resistant to refrigerant R134a and refrigerant oil must be installed.
- There are different connections (outer diameter) for the high pressure and low pressure sides.
- Discharge the refrigerant circuit before removing valves or valve inserts.
- Always screw on the closure caps.
Allocation in the vehicle. Refer to Refrigerant Circuit (vehicle-specific service information).
WARNING:
There is a risk of freezing.
Refrigerant will leak out if refrigerant circuit is not discharged.
Refrigerant must be extracted before opening the refrigerant circuit. If the refrigerant circuit is not opened within 10 minutes of extraction, pressure may form in refrigerant circuit due to evaporation. Extract the refrigerant again.