LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2020 >> SQ8 Premium Plus >> Repair and Diagnosis >> External Pages >> Different car >> Section 32 (Communication (Infotainment - Hazard Alarm Systems)) >> 91 Communication >> Rearview Camera System >> Rearview Camera System, Calibrating >> Rearview Camera -R189-, CALIBRATING

Rearview Camera -R189-, CALIBRATING

WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2024 Audi SQ5, 2024 Audi Q5 e, 2024 Audi Q5, 2023 Audi SQ5, and 2023 Audi Q5 e. However, it is still accessible from the selected car via links, so may be relevant.

-- Establish the requirements. Refer to Calibration Requirements .

-- Connect the Vehicle Diagnostic Tester .

Calibration Tool - Wheel Center Mounting:VAS6350/1A  Installing

-- Check which hole circle the rims have.

-- Equip the Calibration Tool - Wheel Center Mountings:VAS6350/1  appropriately.

-- To do so, secure the three wheel bolt adapters in the hole circle to each Calibration Tool - Wheel Center Mountings:VAS6350/1  .

-- Place the paddle on both Calibration Tool - Wheel Center Mountings:VAS6350/1  and secure them using a clamping screw.

-- Place the Calibration Tool - Wheel Center Mountings:VAS6350/1  onto the wheel bolts on the rear wheels.

The Calibration Tool - Wheel Center Mountings:VAS6350/1  are positioned by the "O-rings" in the adapters and secured.

Fig 1: Identifying Wheel Pick-Ups On Wheel Mounting Bolts At Rear Wheels
GWWN94-10685Courtesy of AUDI OF AMERICA, LLC
NOTE:

Attach the Calibration Tool - Wheel Center Mountings:VAS6350/1  onto the wheels so that any installed "anti-theft" wheel bolts are not connected to the Calibration Tool - Wheel Center Mountings:VAS6350/1  .

-- Adjust the paddles with the aid of clamping screw so that they move freely just above the floor. Check the paddles for ease of movement.

-- Install and align the Calibration Unit:VAS6350A  . Refer to Calibration Unit .

Distance Measurement

-- Switch on the Calibration Tool - Spacing Laser:VAS6350/2  .

The following display appears -1-.

Fig 2: The Following Display Appears -1- :
GWWN91-12610Courtesy of AUDI OF AMERICA, LLC

The display -2- shows how to position the Calibration Tool - Spacing Laser:VAS6350/2A  .

GWWN91-12611Courtesy of AUDI OF AMERICA, LLC

-- Hold the Calibration Tool - Spacing Laser:VAS6350/2A  -2- for the distance measurement on one side of the calibration board flush to the catch bracket, as shown.

GWWN98-10007Courtesy of AUDI OF AMERICA, LLC

-- Push the measurement button briefly.

The laser switches on.

-- Make sure the "laser beam" for the distance measurement contacts the lower enlarged part of the measuring paddle -1-.

If that is not the case, then correct the measuring paddle -1- height using the clamping screw on the Calibration Tool - Wheel Center Mounting:VAS6350/1A  .

-- Use one hand to hold the Calibration Tool - Spacing Laser :VAS6350/2A  firmly in the catch bracket on the Calibration Tool:VAS6350A  ; the laser beam should be seen on the measuring paddle during this.

-- Then press the measurement button for the distance measurement briefly.

-- Write down the value.

-- Repeat this measurement on the other side of the Calibration Tool:VAS6350  in the same way for the rear wheel.

If values are not identical:

-- Readjust the Calibration Tool: VAS6350A  , until the distance values on both sides are identical.

-- Make sure the Calibration Tool - Line Laser:VAS6350/3A  strikes the center above the emblem and that the level indicator remains centered. Adjust if necessary.

Measurement -dimension H- :

Fig 3: Identifying Height Of Calibration Platform, Dimension -H-
GWWA91-11140Courtesy of AUDI OF AMERICA, LLC

-- Measure the height of the Calibration Unit:VAS6350A  , dimension -H- (top edge platform - floor).

-- Make sure the Calibration Tool - Spacing Laser:VAS6350/2  is adjusted correctly (attach with front edge).

The display -2- shows how to position the Calibration Tool - Spacing Laser:VAS6350/2A  .

GWWN91-12611Courtesy of AUDI OF AMERICA, LLC

-- Press the corresponding button.

-- Note the measured distance from the upper edge of the Calibration Tool :VAS6350A  to the floor.

-- Then use commercially available measuring tape to measure the height from the center of the rearview camera lens to the wheel contact surface.

-- Mark the determined height.

The measured distance measurement, the height of the calibration device and the height of the center of the rearview camera lens must be entered in the Vehicle Diagnostic Tester in "mm".

Calibrating Procedure 

The Vehicle Diagnostic Tester is connected.

-- Select the Diagnostic  mode and start the diagnosis.

-- Select the Test plan  tab.

-- Select the Select individual test  button and select the following tree structure consecutively:

The Vehicle Diagnostic Tester continues with the calibrating procedure from here.