Peripheral Camera System, Calibrating

WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2024 Audi SQ5, 2024 Audi Q5 e, 2024 Audi Q5, 2023 Audi SQ5, and 2023 Audi Q5 e. However, it is still accessible from the selected car via links, so may be relevant.

-- The vehicle must be on a level surface.

NOTE:

The vehicle in the illustration is only a basic outline.

GWWA91-12470Courtesy of AUDI OF AMERICA, LLC

-- Roll out the Calibration System:VAS721001  at the left and right near the vehicle.

-- Install the rear and front clamping strip on the Calibration System:VAS721001  .

-- Align the crosshairs -2- to the front axle of the vehicle (center front wheel).

-- Align both calibration devices parallel. The vehicle must be located in the center between both calibration devices.

Pay attention to the following measurement requirements:

-- Set-up the requirement for the vehicle. Refer to Requirement for the calibration of the vehicle .

-- Connect the Vehicle Diagnostic Tester .

Calibrating Procedure 

-- Select the Diagnostic  mode and start the diagnosis.

-- Select the Test plan  tab.

-- Select the Select individual test  button and select the following tree structure consecutively:

The Vehicle Diagnostic Tester continues with the calibrating procedure from here.