Home >> Audi >> 2020 >> SQ8 Premium Plus >> Repair and Diagnosis >> External Pages >> Different car >> Section 316 (Air Conditioning (Heating, Ventilation And Air Conditioning) (Refrigerant Circuit - Actuators)) >> 87 Air Conditioning >> Refrigerant Circuit >> Evacuating And Charging Valve, Removing And Installing, Low And High Pressure Side >> Removing

Evacuating And Charging Valve, Removing And Installing, Low And High Pressure Side: Removing

WARNING: This page is about a different car, the 2023 Audi SQ8, 2023 Audi RS Q8, and 2023 Audi Q8. However, it is still accessible from the selected car via links, so may be relevant.

Vehicles with High-Voltage System

-- Switch off (deactivate) the "parking air conditioner". Refer to Owner's Manual.

-- Switch the ignition on.

-- Vehicles with Heat Pump Function, initiate the A/C system basic setting through the Thermal Management Control Module -J1024- and open the power-activated valves through the stored routine Extract, evacuate and fill the refrigerant circuit  using the Vehicle Diagnostic Tester .

-- Switch off the ignition.

Continuation for all vehicles

GWWA87-11920Courtesy of AUDI OF AMERICA, LLC

This image shows the service connections on a vehicle without a high-voltage system (installed in plenum chamber). On vehicles with a high-voltage system, these connections are installed in the area behind the left headlamp in the engine compartment.

-- Remove the plenum chamber cover if necessary (depending on the component location). Refer to PLENUM CHAMBER COVER, REMOVING AND INSTALLING .

-- Remove the closure caps (with seal) -A or B-.

-- Discharge the refrigerant circuit. Refer to Refrigerant Circuit or A/C SERVICE STATION, USING .

CAUTION:

Danger of frostbite due to refrigerant coming out under pressure.

Frostbite on the skin and other parts of the body is possible.

- Wear safety gloves.

- Wear protective eyewear.

- Evacuate or drain refrigerant and open the refrigerant circuit immediately.

- If more than 10 minutes elapse after extracting or draining the refrigerant and the refrigerant circuit has not been opened, extract or drain the refrigerant again. Pressure develops in the refrigerant circuit due to evaporation.

-- Remove the valve -C- with a suitable Socket from the Refrigerant Sockets:T10364  .