Electro-Hydraulic Engine Mount, Calibrating
WARNING: This page is about a different car, the 2023 Audi Q8. However, it is still accessible from the selected car via links, so may be relevant.
Special tools and workshop equipment required
- Vehicle Diagnostic Tester
Calibration must only be performed on electrohydraulic engine mounts with sensor and actuator for assembly mounts.
Procedure
-- Connect the Vehicle Diagnostic Tester.
-- Select the Diagnostic mode and start the diagnosis.
-- Select the Test plan tab.
-- Select the Select individual test button and select the following tree structure consecutively:
- Drivetrain
- Engine - auxiliary and subsystem
- 01 - OBD-capable systems
- BA - Assembly Mount Control Module
- BA - Assembly Mounts Control Module, Functions
- BA - Performing Basic Setting
- Preform the test