A/C System Particulate Matter Concentration Sensor -G930-, REMOVING AND INSTALLING: Removing
WARNING: This page is about a different car, the 2023 Audi SQ8, 2023 Audi RS Q8, and 2023 Audi Q8. However, it is still accessible from the selected car via links, so may be relevant.
-- Remove the glove compartment. Refer to GLOVE COMPARTMENT, REMOVING AND INSTALLING .
-- Remove the screw clips -A-.
-- Loosen the footwell cover -B- from the heater and A/C unit air intake housing and remove.
-- Release and disconnect the connector -C-.
-- Remove the bolts -A-.
-- Release the retainers -B- and move the sensor -D- to the side.
-- Release the retainer in the direction of -arrow- and disengage the connection -E-.
-- Remove the sensor -D-.