LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2020 >> SQ8 Premium Plus >> Repair and Diagnosis >> External Pages >> Different car >> Section 274 (Air Conditioning (Heating, Ventilation And Air Conditioning) (Actuators - Air Ionization)) >> 87 Air Conditioning >> Air Duct >> Plenum Chamber Water Drain, Removing And Installing >> Removing

Plenum Chamber Water Drain, Removing And Installing: Removing

WARNING: This page is about a different car, the 2023 Audi SQ8, 2023 Audi RS Q8, and 2023 Audi Q8. However, it is still accessible from the selected car via links, so may be relevant.
GWWA87-11862Courtesy of AUDI OF AMERICA, LLC

Vehicles with High-Voltage System

-- Switch off (deactivate) the "parking air conditioner". Refer to Owner's Manual.

Continuation for all vehicles

-- Switch off the ignition.

-- Remove the plenum chamber cover -A-. Refer to PLENUM CHAMBER COVER, REMOVING AND INSTALLING .

-- Depending on the engine and the vehicle version, if necessary loosen the lower plenum chamber bulkhead -D- from the vehicle and pivot it completely to the side (do not open the coolant circuit). Refer to PLENUM CHAMBER COVER, REMOVING AND INSTALLING .

GWWA87-12584Courtesy of AUDI OF AMERICA, LLC

TIP

-- Remove the water drains -B- downward from the openings of the plenum chamber.