Plenum Chamber Water Drain, Removing And Installing: Removing
WARNING: This page is about a different car, the 2023 Audi SQ8, 2023 Audi RS Q8, and 2023 Audi Q8. However, it is still accessible from the selected car via links, so may be relevant.
Vehicles with High-Voltage System
-- Switch off (deactivate) the "parking air conditioner". Refer to Owner's Manual.
Continuation for all vehicles
-- Switch off the ignition.
-- Remove the plenum chamber cover -A-. Refer to PLENUM CHAMBER COVER, REMOVING AND INSTALLING .
-- Depending on the engine and the vehicle version, if necessary loosen the lower plenum chamber bulkhead -D- from the vehicle and pivot it completely to the side (do not open the coolant circuit). Refer to PLENUM CHAMBER COVER, REMOVING AND INSTALLING .
TIP
- The water drains -B- are snapped into the opening of the plenum chamber from below.
- Depending on the engine and the vehicle version the water drains -B- on the installed lower plenum chamber bulkhead -D- is not accessible.
-- Remove the water drains -B- downward from the openings of the plenum chamber.