Add UV-leak detection additive using the in the refrigerant circuit.
Special tools and workshop equipment required
- Leak Detection Kit:VAS 6201A
Leak Detection Kit VAS 6201A contains the following tools. Refer to the Parts Information (Tools; Special Tools and Equipment: A/C and Heating).
- Leak Detection Kit - Hand Pump w/Cartridge -VAS 6201/1-
- Leak Detection Kit - Cartridge -VAS 6201/2- (with UV leak detection additive)
- Leak Detection Kit - Cleaning Solution -VAS 6201/3-
- UV-leak Detection Lamp -VAS 6201/4A-
- Leak Detection Kit - Eye Protection -VAS 6201/6-
- Leak Detection Kit - Sticker -VAS 6201/7-
- Leak Detection Kit - Filler Tube -- VAS 6201/8
- Leak Detection Kit - Hand Protection -VAS 6201/9-
Instructions for how to pour the UV-leak detection additive into the refrigerant circuit using the Leak Detection Kit -VAS 6201A- are given in the following. If the UV-leak detection additive is added to the refrigerant circuit with the help of other tools (for example, with the A/C service station) read the applicable operating instructions.
The following is the specified amount of UV-leak detection additive that is to be added to a refrigerant circuit with a refrigerant oil quantity of 100 to 150cm 3 using the Leak Detection Kit -VAS 6201A- (2.5 ± 0.5 cm3 ). If the refrigerant oil capacity in the refrigerant circuit is larger, then more UV-leak detection additive must be added accordingly (for example, 5.0 ± 0.5 cm3 for a refrigerant circuit with a refrigerant oil capacity of 250 cm 3 . For the relevant refrigerant oil quantities in the refrigerant circuit. Refer to Refer to APPROVED REFRIGERANT OILS AND REFRIGERANT OIL CAPACITIES .
If the UV-leak detection additive is added to the refrigerant circuit with the help of other tools (for example, with the A/C service station), observe the prescribed quantities of UV-leak detection additive given in the corresponding operating instructions.