Home >> Audi >> 2020 >> SQ8 Premium Plus >> Repair and Diagnosis >> External Pages >> Different car >> Section 239 (Air Conditioning (Refrigerant R134A Servicing) (Pressures Checking)) >> 87 Air Conditioning >> Refrigerant Circuit >> Refrigerant Circuit, Determining Leaks >> Leak Detection On Refrigerant Circuit Using Leak Detection System Vas 6201 >> Add UV-leak detection additive using the in the refrigerant circuit.

Add UV-leak detection additive using the in the refrigerant circuit.

WARNING: This page is about a different car, the 2024 Audi SQ7, 2024 Audi Q7, 2023 Audi SQ7, and 2023 Audi Q7. However, it is still accessible from the selected car via links, so may be relevant.

Special tools and workshop equipment required 

Leak Detection Kit VAS 6201A contains the following tools. Refer to the Parts Information (Tools; Special Tools and Equipment: A/C and Heating).

Fig 1: Identifying Leak Detection System VAS 6201
GWWA87-0494Courtesy of AUDI OF AMERICA, LLC
  1. Leak Detection Kit - Hand Pump w/Cartridge -VAS 6201/1-
  2. Leak Detection Kit - Cartridge -VAS 6201/2- (with UV leak detection additive)
  3. Leak Detection Kit - Cleaning Solution -VAS 6201/3-
  4. UV-leak Detection Lamp -VAS 6201/4A-
  5. Leak Detection Kit - Eye Protection -VAS 6201/6-
  6. Leak Detection Kit - Sticker -VAS 6201/7-
  7. Leak Detection Kit - Filler Tube -- VAS 6201/8 
  8. Leak Detection Kit - Hand Protection -VAS 6201/9-
NOTE:

Instructions for how to pour the UV-leak detection additive into the refrigerant circuit using the Leak Detection Kit -VAS 6201A- are given in the following. If the UV-leak detection additive is added to the refrigerant circuit with the help of other tools (for example, with the A/C service station) read the applicable operating instructions.

The following is the specified amount of UV-leak detection additive that is to be added to a refrigerant circuit with a refrigerant oil quantity of 100 to 150cm 3 using the Leak Detection Kit -VAS 6201A- (2.5 ± 0.5 cm3 ). If the refrigerant oil capacity in the refrigerant circuit is larger, then more UV-leak detection additive must be added accordingly (for example, 5.0 ± 0.5 cm3 for a refrigerant circuit with a refrigerant oil capacity of 250 cm 3 . For the relevant refrigerant oil quantities in the refrigerant circuit. Refer to Refer to APPROVED REFRIGERANT OILS AND REFRIGERANT OIL CAPACITIES .

If the UV-leak detection additive is added to the refrigerant circuit with the help of other tools (for example, with the A/C service station), observe the prescribed quantities of UV-leak detection additive given in the corresponding operating instructions.