Home >> Audi >> 2020 >> SQ8 Premium Plus >> Repair and Diagnosis >> External Pages >> Different car >> Section 239 (Air Conditioning (Refrigerant R134A Servicing) (Pressures Checking)) >> 87 Air Conditioning >> Refrigerant Circuit Complaints >> Possible Refrigerant Circuit Concerns >> Possible Complaints

Possible Complaints

WARNING: This page is about a different car, the 2024 Audi SQ7, 2024 Audi Q7, 2023 Audi SQ7, and 2023 Audi Q7. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:

All complaints marked with *. Refer to PRESSURES, CHECKING  "Checking pressures".

If a malfunction occurs at only one evaporator in vehicles with two evaporators, also check the pressures in the refrigerant circuit.

Observe the test requirements. Refer to TEST PREREQUISITES .

Vehicles without High-Voltage System

Vehicles with High-Voltage System

All Vehicles

From these, the following complaints may also occur:

The A/C compressor makes noises

-- Tighten the compressor securing bolts and compressor bracket using a torque wrench.

-- Check the routing of refrigerant pipes; they must not touch other components and must not be subject to strain (align if necessary).

Noise (refrigerant hammer) occurring immediately after switching on air conditioner and/or when cornering or braking

-- Discharge, evacuate and charge refrigerant circuit (too much refrigerant in circuit).

NOTE:

Too much refrigerant oil in the circuit could also cause this problem. This could occur if the amount of refrigerant oil was not adjusted when replacing the A/C compressor.

Water sprays out of vents (in dash panel or footwell) although air conditioning system is otherwise functioning properly:

-- Check proper routing of condensate drain; it must not be crushed or kinked.

-- Check condensation drain valve, it must not be clogged by wax or underbody sealant and must close properly.

-- Check the plenum chamber cover; it must not be damaged and must be properly installed (to stop water running into evaporator).

-- Check the water drains in plenum chamber; they must not be blocked (for example, by leaves).