Specified Values For The Refrigerant Circuit Pressures
High-pressure side:
Increasing from initial pressure (when connecting the pressure gauges) to a maximum of 20 bar (290.08 psi).
Low-pressure side:
Decreasing from initial pressure (when connecting pressure gauges) to the value in the graph.
A -
High Pressure in Bar
B -
Low Pressure in Bar
C -
Permissible Tolerance Range
| Possible deviation from specification | Possible cause of fault | Corrective action |
|---|---|---|
|
Not enough refrigerant in circuit or expansion valve malfunctioning. | -- Extract refrigerant from the refrigerant circuit.
|
|
|
If no malfunction can be found and air conditioner operation is not OK when test is repeated, clean refrigerant circuit by flushing with refrigerant R134a (refer to Refer to REFRIGERANT CIRCUIT, CLEANING (FLUSHING) WITH REFRIGERANT R134A ), or blowing through with compressed air and nitrogen (refer to Refer to REFRIGERANT CIRCUIT, CLEANING WITH COMPRESSED AIR AND NITROGEN ).
| Possible deviation from specification | Possible cause of fault | Corrective action |
|---|---|---|
|
|
-- Check and service the A/C compressor activation and motor. Refer to A/C Compressor (vehicle-specific service information). |
|
-- Clean the refrigerant circuit by flushing with refrigerant R134a (refer to Refer to REFRIGERANT CIRCUIT, CLEANING (FLUSHING) WITH REFRIGERANT R134A ) or blow through using compressed air and nitrogen (refer to Refer to REFRIGERANT CIRCUIT, CLEANING WITH COMPRESSED AIR AND NITROGEN ).-- Replace the hose or pipe if kinked or constricted. | |
|
-- Replace the A/C compressor. |
| Possible deviation from specification | Possible cause of fault | Corrective action |
|---|---|---|
|
|
-- Run a hand over refrigerant circuit to check for differences in temperature. Refer to SYSTEM OVERVIEW - REFRIGERANT CIRCUIT
(vehicle-specific service information).
|
If the operation is not OK after cleaning refrigerant circuit by flushing with R134a (refer to Refer to REFRIGERANT CIRCUIT, CLEANING (FLUSHING) WITH REFRIGERANT R134A ), or blowing through using compressed air and nitrogen (refer to Refer to REFRIGERANT CIRCUIT, CLEANING WITH COMPRESSED AIR AND NITROGEN ), expansion valve must be replaced.
| Possible deviation from specification | Possible cause of fault | Corrective action |
|---|---|---|
|
|
-- Replace the receiver/dryer (with dryer) and evacuate the refrigerant circuit for a minimum of three hours (see notes).-- Examine the expansion valve for dirt or corrosion; replace if necessary.-- Clean the refrigerant circuit by flushing with refrigerant R134a (refer to Refer to REFRIGERANT CIRCUIT, CLEANING (FLUSHING) WITH REFRIGERANT R134A ) or blow through using compressed air and nitrogen (refer to Refer to REFRIGERANT CIRCUIT, CLEANING WITH COMPRESSED AIR AND NITROGEN ). |
|
It is not initially necessary to clean the refrigerant circuit by flushing with refrigerant R134a (refer to Refer to REFRIGERANT CIRCUIT, CLEANING (FLUSHING) WITH REFRIGERANT R134A ), or blowing through using compressed air and nitrogen (refer to Refer to REFRIGERANT CIRCUIT, CLEANING WITH COMPRESSED AIR AND NITROGEN ) when this problem occurs since normally, there is only a small quantity of moisture in the system which can be removed by lengthy evacuation.
If problem involving moisture in refrigerant circuit only occurs after a lengthy operating period or only infrequently (low pressure drops below specification and evaporator ices up), it is sufficient to replace the dryer (adjust quantity of refrigerant oil). Refrigerant circuit is then to be evacuated for at least three hours.
| Possible deviation from specification | Possible cause of fault | Corrective action |
|---|---|---|
|
|
-- Extract refrigerant from the refrigerant circuit.
|
If air conditioner operation is not OK when test is repeated, install the old expansion valve, clean refrigerant circuit by flushing using refrigerant R134a (refer to Refer to REFRIGERANT CIRCUIT, CLEANING (FLUSHING) WITH REFRIGERANT R134A ), or blowing through with compressed air and nitrogen (refer to Refer to REFRIGERANT CIRCUIT, CLEANING WITH COMPRESSED AIR AND NITROGEN ). Then replace the A/C compressor and receiver/dryer.
| Possible deviation from specification | Possible cause of fault | Corrective action |
|---|---|---|
|
A/C compressor faulty. | -- Clean the refrigerant circuit by flushing with refrigerant R134a (refer to Refer to REFRIGERANT CIRCUIT, CLEANING (FLUSHING) WITH REFRIGERANT R134A ) or blow through using compressed air and nitrogen (refer to REFRIGERANT CIRCUIT, CLEANING WITH COMPRESSED AIR AND NITROGEN ).-- Replace the A/C compressor and receiver/dryer. |
| Possible deviation from specification | Possible cause of fault | Corrective action |
|---|---|---|
|
Expansion valve or A/C compressor faulty. | -- Replace the expansion valve.-- Charge the refrigerant circuit.-- Repeat the test. |
If air conditioner operation is not OK when test is repeated, install the old expansion valve, clean refrigerant circuit by flushing using refrigerant R134a (refer to Refer to REFRIGERANT CIRCUIT, CLEANING (FLUSHING) WITH REFRIGERANT R134A ), or blowing through with compressed air and nitrogen (refer to Refer to REFRIGERANT CIRCUIT, CLEANING WITH COMPRESSED AIR AND NITROGEN ). Then replace the A/C compressor and receiver/dryer.
With this malfunction, evaporator may ice up although the quantity of refrigerant in circuit is OK.
| Possible deviation from specification | Possible cause of fault | Corrective action |
|---|---|---|
|
Too much refrigerant oil in the circuit. | -- Discharge the refrigerant circuit.-- Clean the refrigerant circuit by flushing with refrigerant R134a (refer to Refer to REFRIGERANT CIRCUIT, CLEANING (FLUSHING) WITH REFRIGERANT R134A ) or blow through using compressed air and nitrogen (refer to Refer to REFRIGERANT CIRCUIT, CLEANING WITH COMPRESSED AIR AND NITROGEN ). |
|
Overfilling with refrigerant oil can occur if, for example, the compressor has been replaced without adjusting the quantity of refrigerant oil.
If there is too much refrigerant oil in the circuit, the compressor must be drained and the receiver/dryer must be replaced. After cleaning the refrigerant circuit by flushing with refrigerant R134a (refer to Refer to REFRIGERANT CIRCUIT, CLEANING (FLUSHING) WITH REFRIGERANT R134A ), or blowing through using compressed air and nitrogen (refer to Refer to REFRIGERANT CIRCUIT, CLEANING WITH COMPRESSED AIR AND NITROGEN ) fill the circuit with the correct quantity of refrigerant oil. Refer to Refer to APPROVED REFRIGERANT OILS AND REFRIGERANT OIL CAPACITIES .