LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2020 >> SQ8 Premium Plus >> Repair and Diagnosis >> External Pages >> Different car >> Section 236 (Brake System Hydraulic Components) >> 47 Hydraulic Components >> Vacuum System >> Vacuum Pump, Removing And Installing >> Vacuum Pump, Removing And Installing, Vehicle With 4.0L TFSI Engine >> Removing

Vacuum Pump, Removing And Installing, Vehicle With 4.0L TFSI Engine: Removing

WARNING: This page is about a different car, the 2024 Audi SQ7, 2024 Audi Q7, 2023 Audi SQ7, and 2023 Audi Q7. However, it is still accessible from the selected car via links, so may be relevant.

-- Remove the fan shroud. Refer to FAN SHROUD, REMOVING AND INSTALLING .

-- Free up the vacuum line -3- on the wiring duct.

GWWA24-12235Courtesy of AUDI

-- Disconnect the connectors and free them up:

1 -  Oil Pressure Sensor -G10-

2 -  Map Controlled Engine Cooling Thermostat -F265-

6 -  Recirculation Valve, Bank 2 -N626-

9 -  Oil Pressure Regulation Valve -N428-

-- Disconnect the connector -5- for the Tank Ventilation Pressure Sensor 2 -G951- and free up the wire on the wiring duct.

-- Remove the connector -8- for the Oxygen Sensor 1 Before Catalytic Converter -GX10- from the bracket and disconnect and free up the wire.

-- Remove the bolts -4- and unclip the wiring duct from the bracket in direction of -arrow-.

-- Push the wiring duct upward and disconnect the connector -7- for the Engine Temperature Sensor -G407-.

-- Release the retainer in direction of -arrow B- and disconnect the vacuum line -2- without damaging it.

GWWA47-10313Courtesy of AUDI

-- Remove the vacuum hose -3- without damaging it.

-- Remove the bolts -A arrows- and the vacuum pump -1-.