Home >> Audi >> 2020 >> SQ8 Premium Plus >> Repair and Diagnosis >> External Pages >> Different car >> Section 211 (Air Conditioning (Refrigerant R1234YF Servicing) (Refrigerant Circuit)) >> 87 Air Conditioning >> Refrigerant Circuit >> Leaks, Finding >> Leaks, Finding With UV Leak Detection System >> Add the UV leak detection additive to the refrigerant circuit using the

Add the UV leak detection additive to the refrigerant circuit using the

WARNING: This page is about a different car, the 2024 Audi SQ7, 2024 Audi Q7, 2023 Audi SQ7, and 2023 Audi Q7. However, it is still accessible from the selected car via links, so may be relevant.

-- Add the UV-leak detection additive and the specified refrigerant quantity into the refrigerant circuit using the A/C Service Station. Refer to REFRIGERANT CIRCUIT, CHARGING and Technical Data (vehicle-specific service information).

NOTE:

The quantity of UV leak detection additive which is filled on a refrigerant circuit with a refrigerant oil quantity up to 150 cm3 is 3.0 + /- 0.5 ml (cm3 ). If the refrigerant oil capacity in the refrigerant circuit is larger, then more UV leak detection additive must be added accordingly (for example, 5.0 ± 0.5 (cm3 ) for a refrigerant circuit with a refrigerant oil capacity of 250 cm 3 . When filling the UV leak detection additive using an A/C Service Station the set quantity in the A/C Service Station can vary for this reason pay attention to the corresponding Owner's Manual. Refer to A/C Service Station Owner's Manual.

The relative refrigerant oil quantity in the refrigerant circuit can be found in the vehicle-specific service information. Refer to Technical Data (vehicle-specific service information).

If UV leak detection additive was filled already in a refrigerant circuit for an earlier repair, note the following: only add new UV leak detection additive if the refrigerant oil will be replaced. If only a portion of the refrigerant oil was replaced, only add a proportionate amount of the UV leak detection additive. For example, if 50 ml of refrigerant oil was replaced in a vehicle with 150 ml, add only 1.0 ml (cm3 ) of UV leak detection additive.

The Leak Detection System has the following components:

Fig 1: Identifying Leak Detection System VAS 6201
GWWA87-0494Courtesy of AUDI OF AMERICA, LLC
NOTE:

Ignore items -1-,-2- and -7- in the image.

Special tools and workshop equipment required 

-- Evacuate the refrigerant circuit according to the procedure and fill with UV-leak detection additive and refrigerant. Refer to REFRIGERANT CIRCUIT, EVACUATING  and Refer to REFRIGERANT CIRCUIT, CHARGING .

-- Wait until the pressure in the high and low pressure side have equalized.

-- Disconnect the A/C Service Station from the refrigerant circuit and turn it off. Refer to A/C SERVICE STATION, SWITCHING OFF AND DISCONNECTING FROM REFRIGERANT CIRCUIT .

-- Apply a label near the service connections stating that UV leak detection additive was added to the refrigerant circuit.

Fig 2: Identifying Leak Detection Additive Label
GWWA87-0495Courtesy of AUDI OF AMERICA, LLC

-- Remove the residual UV leak detection additive for example with absorbent paper from the service connection and the surrounding area and clean using Leak Detection Kit - Cleaning Solution -VAS 6201/3-.

-- Seal the service connection using closure caps.

-- Start the A/C system.

-- Operate the A/C system for at least 60 minutes with the A/C compressor switched on.

-- Check for leaks on the refrigerant circuit using UV Lamp. Refer to Check for leaks on the refrigerant circuit using .