LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2020 >> SQ8 Premium Plus >> Repair and Diagnosis >> External Pages >> Different car >> Section 176 (Air Conditioning (Heating, Ventilation And Air Conditioning) (Actuators - Air Ionization)) >> 87 Air Conditioning >> Front Heater And A/C Unit >> Fresh Air Blower -V2- WITH Fresh Air Blower Control Module -J126-, EMOVING AND INSTALLING >> Removing

Fresh Air Blower -V2- WITH Fresh Air Blower Control Module -J126-, EMOVING AND INSTALLING: Removing

WARNING: This page is about a different car, the 2024 Audi SQ7, 2024 Audi Q7, 2023 Audi SQ7, and 2023 Audi Q7. However, it is still accessible from the selected car via links, so may be relevant.

Vehicles with High-Voltage System

-- Switch off (deactivate) the "parking air conditioner".Refer to Owner's Manual.

Continuation for all vehicles

-- Position the front passenger seat as far back as possible.

-- Switch off the ignition.

-- Remove the glove compartment. Refer to GLOVE COMPARTMENT, REMOVING AND INSTALLING .

-- Remove the footwell vent on the front passenger side. Refer to FRONT PASSENGER SIDE FOOTWELL VENT, REMOVING AND INSTALLING .

-- If equipped, remove the air duct for the glove compartment cooling. Refer to AIR GUIDE FOR GLOVE COMPARTMENT COOLING, REMOVING AND INSTALLING .

-- Release the connector -A- and disconnect from the Fresh Air Blower -V2- (with the Fresh Air Blower Control Module -J126-)-C-.

GWWA87-11823Courtesy of AUDI OF AMERICA, LLC

-- Remove the insulation -B-.

-- Remove the bolts -A-.

GWWA87-11824Courtesy of AUDI OF AMERICA, LLC
CAUTION:

There is a risk of burns from the hot radiating surface of the fresh air blower control module.

It is possible to burn hands.

- Wear safety gloves.

CAUTION:

Risk of damaging the fresh air blower if operated incorrectly.

Imbalance and problems during operation is possible.

- Avoid using force on the fan wheel.

- Never move the balancing weight on the fan wheel.

- Do not place the fresh air blower on the fan wheel.

-- Remove the Fresh Air Blower -V2- (with the Fresh Air Blower Control Module -J126-)-B- carefully from air intake housing -C-.