Home >> Audi >> 2020 >> SQ8 Premium Plus >> Repair and Diagnosis >> External Pages >> Different car >> Section 176 (Air Conditioning (Heating, Ventilation And Air Conditioning) (Actuators - Air Ionization)) >> 87 Air Conditioning >> Front Heater And A/C Unit >> Condensation Water Drain, Removing And Installing >> Removing

Condensation Water Drain, Removing And Installing: Removing

WARNING: This page is about a different car, the 2024 Audi SQ7, 2024 Audi Q7, 2023 Audi SQ7, and 2023 Audi Q7. However, it is still accessible from the selected car via links, so may be relevant.

Vehicles with High-Voltage System

-- Switch off (deactivate) the "parking air conditioner".Refer to Owner's Manual.

Continuation for all vehicles

-- Switch off the ignition.

Front passenger side

GWWA68-10780Courtesy of AUDI OF AMERICA, LLC

-- Unclip the inner front passenger side cover -1- using the Trim Removal Wedge:3409  from the instrument panel cover in the direction of -arrows-.

Driver side, LHD

-- Remove accelerator pedal. Refer to ACCELERATOR MECHANISM .

Driver side, RHD

-- Remove the driver side instrument panel cover. Refer to DRIVER SIDE INSTRUMENT PANEL COVER, REMOVING AND INSTALLING .

Continuation for all vehicles

GWWA87-12566Courtesy of AUDI OF AMERICA, LLC

-- Pull the carpet in the area of the center tunnel slightly to the side.

-- Unclip the support for the A/C unit -1- downward in the direction of -arrow A- from the heater and A/C unit -2- and remove in the direction of -arrow B-.

-- Check that both the condensation water drain hoses -B- are properly routed and for dirt. Correct, for example, if there is a constriction.

GWWA87-11825Courtesy of AUDI OF AMERICA, LLC

-- Cover the area under both openings -D- (for water drain hose opening -C-)with absorbent paper (so that any water does not get under the carpet).

-- Remove both condensation water drain hoses -B-.

-- Check both heater and A/C unit condensation water drains -A- for contamination (for example, using a piece of wire).

-- Check the gap between the insulation mat installed in the center tunnel -E- and the end of the condensation water drain hose -C- above the openings -D- in the floor panel -F- ; the gap must be large enough so that the condensation water can flow out of the condensation water drain hose -B-.