LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2020 >> SQ8 Premium Plus >> Repair and Diagnosis >> External Pages >> Different car >> Section 174 (Air Conditioning (Refrigerant R134A Servicing) (General Information)) >> 87 Air Conditioning >> Refrigerant Circuit General Information >> Pressure Gauge, Tests And Measurements >> Pressure Gauge Uses

Pressure Gauge Uses

WARNING: This page is about a different car, the 2024 Audi SQ7, 2024 Audi Q7, 2023 Audi SQ7, and 2023 Audi Q7. However, it is still accessible from the selected car via links, so may be relevant.

Pressure and Temperature Measurement at Refrigerant Circuit

NOTE:

The relationship between pressure and temperature indicated on the gauges only exists in a refrigerant circuit that contains liquid or vapor, but not gas. In a gaseous state, the temperature is approximately 10 °C to 30 °C (50 °F to 86 °F) higher than indicated on the pressure gauge.

Verification of Refrigerant in a Closed Reservoir

Refrigerant R134a is present in a reservoir canister or in a refrigerant circuit when the temperature indicator on the pressure gauge matches the refrigerant temperature (standing fluid adopts the ambient temperature).

A closed cylinder or a refrigerant circuit that has been switched off is empty when the temperature indicator on the pressure gauge is below the temperature of the refrigerant.

NOTE: