LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2020 >> SQ8 Premium Plus >> Repair and Diagnosis >> External Pages >> Different car >> Section 165 (Starter, Generator And Cruise Control) >> 27 Starter, Generator And Cruise Control >> Battery, Charging >> Battery Charger :VAS5900 >> BATTERY, CHARGING WITH Battery Charger:VAS5900

BATTERY, CHARGING WITH Battery Charger:VAS5900

WARNING: This page is about a different car, the 2024 Audi SQ7, 2024 Audi Q7, 2023 Audi SQ7, and 2023 Audi Q7. However, it is still accessible from the selected car via links, so may be relevant.

Special tools and workshop equipment required 

WARNING:

Risk of injury. Follow all warning messages and safety precautions. Refer to WARNINGS AND SAFETY PRECAUTIONS .

WARNING:

Do not check or charge a Battery -A- when the visual indicator has >>no color or is bright yellow<<. Jump starting must not be used!

There is a risk of explosion during testing, charging or jump starting.

These Batteries -A- must be replaced.

NOTE:

The Battery -A- temperature must be at least 10 °C (50 °F).

Procedure

-- Turn off the ignition and all electrical consumers and remove the ignition key.

-- Connect the Battery Charger:VAS5900  to the power supply. The last selected mode is shown on the display. Refer to Battery Charger .

-- Set the battery type with the INFO  button.

Fig 2: Identifying Battery Type Symbols
GWWN27-10169Courtesy of AUDI

The symbol -1- for "standard charge of wet batteries" or the symbol -2- for "standard charge of Gel/Absorbent Glass Mat (AGM) batteries" is indicated in the display.

-- Set the battery capacity (Ah) on the Battery -A- to be charged with the corresponding ↑  button or ↓  button.

-- Connect the red charge terminal (+) to the positive terminal of the Battery -A-.

NOTE:

On vehicles with a Start/Stop function and an installed Battery Monitoring Control Module -J367-, the black charge terminal (-) must be connected to the body ground. The Start/Stop system will malfunction when it is connected to the Battery -A- negative terminal.

-- Connect the black charge terminal (-) to the negative terminal of the Battery -A- /negative connector.

The Battery Charger:VAS5900  recognizes the nominal voltage of the connected Battery -A- (6 V/12 V/24 V) and begins the charging process automatically.

The Battery Charger:VAS5900  begins the "final charging" when the charge level is approximately 80 to 85%. The fourth bar is indicated on the display -1-. The Battery -A- is ready to be used.

Fig 3: Charging Unit Display, Charge Condition Approx. 80 - 85 %
GWWN27-10170Courtesy of AUDI

With a charge status of 100%, all bars are indicated on the display -1-.

Fig 4: Charging Unit Display, Charge Condition 100 %
GWWN27-10180Courtesy of AUDI
NOTE:

With the "standard charge", parallel operation of electrical consumers during the charging process is possible. The charging time is lengthened by this.

Depending on the battery type, the Battery Charger:VAS5900  switches to maintenance charging after 1 to 7 hours. To reach a 100% charge level, the Battery -A- should remain connected to the :VAS5900  .

Possible malfunctions and how they are handled

  1. Displayed voltage does not match the nominal voltage:

    -- Hold down the ↑  button or ↓  button until the charging process begins.

  2. Displayed battery voltage does not match the nominal voltage - the charging process has already begun:

    -- Press the START/STOP  button two times.

    -- Hold down the ↑  button or ↓  button until the charging process begins again.

  3. The Battery Charger:VAS5900  does not recognize the Battery -A-, if the battery voltage is less than 2V:

    The display remains unchanged.

    The selected battery type and Ampere hours (Ah) are displayed.

Battery -A- charging, ending

-- Press the START/STOP  -button.

-- Remove the charging clamps from the battery terminals.

-- Disconnect the :VAS5900  from the power.