LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2020 >> SQ8 Premium Plus >> Repair and Diagnosis >> External Pages >> Different car >> Section 119 (Cooling System (4-Cylinder Direct Injection 2.0L 4V TFSI Engine (Ea 888EVO4)) (DPVA)) >> 19 Cooling System >> Coolant Pump/Coolant Thermostat >> Thermal Management Coolant Temperature Sensor 8 -G968-, REMOVING AND INSTALLING >> Thermal Management Coolant Temperature Sensor 8 -G968-, REMOVING AND INSTALLING, AUDI Q5

Thermal Management Coolant Temperature Sensor 8 -G968-, REMOVING AND INSTALLING, AUDI Q5

WARNING: This page is about a different car, the 2024 Audi Q5 and 2023 Audi Q5. However, it is still accessible from the selected car via links, so may be relevant.

Shop Crane - Drip Tray:VAS 6208 

Fig 1: Identifying Drip Tray
GWWW00-11209Courtesy of AUDI OF AMERICA, LLC

Procedure 

-- To remove any residual pressure in the cooling system, cut the seal tab -3- and open the coolant expansion tank cap -1- for the high-voltage system cooling circuit.

GWWA19-13203Courtesy of AUDI OF AMERICA, LLC

-- Disconnect the connector -1-.

GWWA19-13147Courtesy of AUDI OF AMERICA, LLC
CAUTION:

Collecting coolant and determining volumes.

-- Place the Shop Crane - Drip Tray:VAS 6208  underneath.

-- Remove the bolt -2-, and remove the Thermal Management Coolant Temperature Sensor 8 -G968-.

-- To prevent coolant loss, install the new coolant temperature sensor immediately.

-- Add the coolant. Refer to COOLANT, ADDING AND COOLING SYSTEM, BLEEDING, HIGH-VOLTAGE SYSTEM COOLING CIRCUIT .

-- Drain and fill the coolant for the high-voltage system cooling circuit only if the coolant loss is greater than 500 ml. Refer to COOLANT, DRAINING, HIGH-VOLTAGE COOLING CIRCUIT  and Refer to COOLING SYSTEM, FILLING, HIGH-VOLTAGE SYSTEM COOLING CIRCUIT .

Tightening Specifications