Home >> Audi >> 2020 >> SQ8 Premium Plus >> Repair and Diagnosis >> External Pages >> Different car >> Section 119 (Cooling System (4-Cylinder Direct Injection 2.0L 4V TFSI Engine (Ea 888EVO4)) (DPVA)) >> 19 Cooling System >> Coolant Pump/Coolant Thermostat >> Coolant Change-Over Valve 2 -N633-, REMOVING AND INSTALLING >> Coolant Change-Over Valve 2 -N633-, REMOVING AND INSTALLING, AUDI Q5 >> Removing

Coolant Change-Over Valve 2 -N633-, REMOVING AND INSTALLING, AUDI Q5: Removing

WARNING: This page is about a different car, the 2024 Audi Q5 and 2023 Audi Q5. However, it is still accessible from the selected car via links, so may be relevant.

-- Remove the right front wheel spoiler. Refer to OVERVIEW - FRONT WHEEL HOUSING LINER .

-- If installed, remove the Engine Sound Generator Actuator 1 -R257-. Refer to Engine Sound Generator Actuator 1 -R257-, REMOVING AND INSTALLING, AUDI Q5 .

-- Disconnect the connector -2-.

GWWA19-13195Courtesy of AUDI OF AMERICA, LLC

-- Clamp off the coolant hoses using the Hose Clamps - Up To 25mm:3094  .

CAUTION:

Collecting coolant and determining volumes.

-- Place the Shop Crane - Drip Tray:VAS 6208  underneath.

-- Loosen the hose clamps -1- and remove the coolant hoses.

-- Remove the bolts -arrows- to do so counterhold if necessary.

-- Remove the Coolant Change-Over Valve 2 -N633-.