Lane Change Assistance, Calibrating

WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2024 Audi SQ5, 2024 Audi Q5 e, 2024 Audi Q5, 2023 Audi SQ5, and 2023 Audi Q5 e. However, it is still accessible from the selected car via links, so may be relevant.

Special tools and workshop equipment required 

Conditions

-- The Lane Change Assistance Control Module -J769- / Lane Change Assistance Control Module 2 -J770- must be calibrated using the Vehicle Diagnostic Tester during the following conditions:

Preparing for Calibration

GWWA96-11470Courtesy of AUDI OF AMERICA, LLC
  1. Calibration Tool - Spacing Laser:VAS 6350/2 
    • For distance measurement
    • Usage information. Refer to the Calibration ToolVAS 6350 Owner's Manual.
  2. Calibration Unit:VAS 6350A 
  3. Level
    • On the Calibration Tool:VAS 6350A 
    • For checking the horizontal position of the Calibration Tool:VAS 6350A 
  4. Stop bracket
    • To mount the Calibration Tool - Spacing Laser -VAS 6350/2- for the distance measurement
    • Distance to the Calibration Tool - Wheel Center Mountings -VAS 6350/1- on the rear wheels: dimension -a- = 1700 ± 2 mm
  5. Calibration Tool - Lane Change Calibration Tool:VAS 6350/4 
    • Is moved from one side of the measuring field to the other during calibration
    • When installed correctly, the vehicle electrical system voltage line must be connected at lower left of the calibration device (as seen in direction of travel)
  6. Emblem
    • The laser pointer is aligned to the center of the emblem
  7. Calibration Tool - Wheel Center Mountings:VAS 6350/1 
    • With wheel bolt adapter and measuring paddle
  8. Measuring Scale
    • For positioning the Calibration Tool - Lane Change Calibration Tool:VAS 6350/4 
  9. Calibration Tool - Linear Laser:VAS 6350/3A 
    • With "laser protective eyewear"
    • On the Calibration Tool:VAS 6350A 
    • Turning on and off. Refer to the Calibration ToolVAS 6350 Operating Instructions.
  10. Plastic Foot
    • Quantity: 3
    • Can be adjusted when setting the horizontal position of the Calibration Tool:VAS 6350A 

Preliminary Work

-- Move the vehicle onto a solid, flat surface.

-- Activate the "standard vehicle height" on vehicles with air suspension (MMI setting: automatic or comfort).

-- Apply the parking brake - the vehicle must not move during the measurement.

-- Place the front wheels in a straight-ahead position - steering wheel in neutral position.

-- Connect the Vehicle Diagnostic Tester. Refer to Vehicle Diagnostic Tester .

TIP:

If a malfunction message appears in the display, refer to the Vehicle Diagnostic Tester Operating Instructions.

-- Switch the ignition on.

-- Remove the label with the metal foil from the bumper cover, if necessary.

-- Secure three suitable wheel bolt adapters for the wheel bolts on each Calibration Tool - Wheel Center Mountings -VAS 6350/1-.

Fig 2: Identifying Wheel Pick-Ups On Wheel Mounting Bolts At Rear Wheels
GWWN94-10685Courtesy of AUDI OF AMERICA, LLC

-- Insert the measuring paddle at both Calibration Tool - Wheel Center Mountings -VAS 6350/1- and secure with the locking nut.

-- Place the Calibration Tool - Wheel Center Mountings -VAS 6350/1- onto the wheel bolts on both rear wheels.

-- Place the Calibration Tool - Wheel Center Mountings -VAS 6350/1- on the wheels so that the "anti-theft wheel bolts" are not connected to the wheel center mounting.

-- Adjust the measuring paddle using the locking nuts so that they move freely just above the floor.

-- Position the Calibration Tool:VAS 6350A  at distance -a- to the rear wheels.

Fig 3: Positioning Calibration Device VAS 6350
GWWA96-10536Courtesy of AUDI OF AMERICA, LLC

-- Switch on the Calibration Tool - Spacing Laser:VAS 6350/2  with the ON  button.

Fig 4: Identifying Laser Display
GWWN94-10681Courtesy of AUDI OF AMERICA, LLC

Display on the Calibration Tool - Spacing Laser:VAS 6350/2A  :

-- For distance measurement, hold the Calibration Tool - Spacing Laser:VAS 6350/2  -item 2- flush to the left catch bracket as shown.

Fig 5: Holding Distance Laser VAS 6350/2 Flush To Catch Bracket
GWWA96-10535Courtesy of AUDI OF AMERICA, LLC

-- Make sure the "laser beam" for the distance measurement contacts the enlarged lower part on the paddle -1-.

If this is not the case, measuring paddle height must be corrected using locking nuts on Wheel Center Mounting -VAS 6350/1-.

-- Briefly press the ON  button for distance measurement.

Fig 6: Identifying Display On VAS 6350/2
GWWA96-10289Courtesy of AUDI OF AMERICA, LLC

Display on the Calibration Tool - Spacing Laser :VAS 6350/2A  :

-- Repeat the measuring procedure from the right stop bracket to the right rear wheel.

If both measured values are not the same, adjust the Calibration Tool:VAS 6350A  accordingly.

Calibrating Procedure 

The Vehicle Diagnostic Tester is connected.

-- Select and start the Diagnostic  operating mode.

-- Select the Test plan  tab.

-- Select the Select individual test  button and select the following tree structure consecutively:

-- Start the selected program and follow the instructions on the Vehicle Diagnostic Tester display.

TIP:

-- Secure the Calibration Tool - Lane Change Calibration Tool -VAS 6350/4- to the mount for the Calibration Tool:VAS 6350  at the rear left.

GWWA96-11376Courtesy of AUDI OF AMERICA, LLC

Dimension -a- is measured from the upper edge of the calibration device to the floor.

Model Q5, all versions
Adjustment dimension height in mm dimension -a- 602 (23.70 in.)

-- The indicator on the base of the Calibration Tool - Lane Change Calibration Tool -VAS 6350/4- must align with the adjustment dimension on the measuring scale -1- on the measuring field -arrow-.

Model Q5, all versions
Left adjustment dimension read in mm on the measuring scale -1- 770 (30.31 in.)

-- Connect the Calibration Tool - Lane Change Calibration Tool -VAS 6350/4- to the vehicle electrical system voltage.

-- Bring Calibration Tool:VAS 6350  into horizontal position by turning the plastic feet.

Fig 7: Identifying Bubble Level (Sight Glass) On Calibration Tool VAS 6350
GWWN94-10686Courtesy of AUDI OF AMERICA, LLC

-- Turn on the Calibration Tool - Linear Laser -VAS 6350/3A- on the Calibration Unit:VAS 6350A  .

GWWA96-11453Courtesy of AUDI OF AMERICA, LLC

-- Wear "laser protective eyewear".

-- Align the Calibration Tool:VAS 6350A  so that the Calibration Tool - Linear Laser -VAS 6350/3A- strikes the center of the emblem on the rear lid.

-- Check the distance on the left and right sides between the catch brackets of the Calibration Unit:VAS 6350A  and the measuring paddles -1- on wheel mountings again.

Fig 8: Holding Distance Laser VAS 6350/2 Flush To Catch Bracket
GWWA96-10535Courtesy of AUDI OF AMERICA, LLC

Calibration Procedure 

The following should not occur during the calibration procedure:

Procedure 

Fig 9: Identifying Assistance Calibration Device VAS 6350/4 Components
GWWA96-10358Courtesy of AUDI OF AMERICA, LLC

-- Turn on the Calibration Tool - Lane Change Calibration Tool -VAS 6350/4- at the voltage switch -3-.

-- The red LED -2- is illuminated: check the Calibration Tool - Lane Change Calibration Tool -VAS 6350/4-.

-- Follow the instructions in the vehicle diagnostic tester display.

During the program sequence, there is a prompt to switch the Calibration Tool - Lane Change Calibration Tool -VAS 6350/4- from the left to the right side of the Calibration Tool:VAS 6350  .

GWWA96-11375Courtesy of AUDI OF AMERICA, LLC

-- Turn off the Calibration Tool - Lane Change Calibration Tool -VAS 6350/4- and reposition the calibration tool.

Dimension -a- is measured from the upper edge of the calibration device to the floor.

Model Q5, all versions
Adjustment dimension height in mm dimension -a- 602 (23.70 in.)

-- The indicator on the base of the Calibration Tool - Lane Change Calibration Tool -VAS 6350/4- must align with the adjustment dimension on the measuring scale -1- on the measuring field -arrow-.

Model Q5, all versions
Right adjustment dimension read in mm on the measuring scale -1- 770 (30.31 in.)

-- Turn on the Calibration Tool - Lane Change Calibration Tool -VAS 6350/4- at the voltage switch -3-.

Fig 10: Identifying Assistance Calibration Device VAS 6350/4 Components
GWWA96-10358Courtesy of AUDI OF AMERICA, LLC

-- Follow the instructions in the vehicle diagnostic tester display.

-- After calibrating the lane change assistance successfully, end "calibration", switch off the ignition and disconnect the diagnostic connector.