Checking The Pressure Relief Valve In The Version 1 Cap
-- Position the :VAG1274B with the :VAG1274B/15 on the cap.
-- Generate approximately 2 bar (29 psi) pressure using the cooling system tester hand pump.
Blue Cap:
- The pressure must lower to 1.4 to 1.6 bar (20.30 to 23.20 psi) and stay there.
-- If the pressure relief valve does not react as specified, replace the cap.
Black Cap:
- The pressure must lower to 1.6 to 1.8 bar (23.2 to 26.1 psi) and stay there.
-- If the pressure relief valve does not react as specified, replace the cap.
Checking The Pressure Relief Valve In The Version 2 Cap:
-- Position the :VAG1274B with the :VAG1274/9 on the cap.
-- Generate pressure with the cooling system tester hand pump.
Blue Cap:
- The pressure release valve must open at 1.4 to 1.6 bar (20.30 to 23.20 psi).
-- If the pressure relief valve does not react as specified, replace the cap.
Black Cap:
- The pressure release valve must open at 1.6 to 1.8 bar (23.2 to 26.1 psi).
-- If the pressure relief valve does not react as specified, replace the cap.
Additional procedures depending on the model: COOLING SYSTEM, CHECKING FOR LEAKS .