RECIRCULATION Valve, Removing And Installing
Recirculation Valve, Bank 1 -N625-, removing
-- Audi A8: remove the upper air duct pipe. Refer to UPPER AIR DUCT PIPE, REMOVING AND INSTALLING, AUDI A8 .
-- Audi S8: remove the right upper air duct pipe. Refer to UPPER AIR DUCT PIPE, REMOVING AND INSTALLING, AUDI S8 .
-- Remove the crankcase ventilation hose -1- by pressing the release buttons on both sides.
-- Disconnect the connector -2-.
-- Remove the bolts -arrows-, remove the heat shield -3- with the recirculation valve -4-.
TIP:
- If the distance between the recirculation valve and the engine lifting eye is too narrow to position the tool, then the turbocharger must be removed.
Recirculation Valve, Bank 2 -N626-, Removing
-- Remove the left turbocharger. Refer to TURBOCHARGER, REMOVING AND INSTALLING, CYLINDER BANK 2 (LEFT) .
-- Remove the bolts -arrows-, remove the heat shield -1- with the recirculation valve -2-.
Installing
Install in the reverse order of removal while noting the following:
- Replace the O-ring after removal.
-- Install the upper air duct pipe. Refer to AIR DUCT PIPE, REMOVING AND INSTALLING .
Tightening Specifications
- Refer to OVERVIEW - TURBOCHARGER .