Home >> Audi >> 2020 >> S4 Prestige >> Repair and Diagnosis >> External Pages >> Different car >> Section 69 (Charging System (Battery, Starter And Generator) & Cruise Control (1 Of 2)) >> 27 Battery, Starter, Generator, Cruise Control >> Battery >> Battery, Removing And Installing >> Battery -A-, REMOVING AND INSTALLING, 0K4 AND VH2 >> Installing

Battery -A-, REMOVING AND INSTALLING, 0K4 AND VH2: Installing

WARNING: This page is about a different car, the 2021 Audi S4 and 2021 Audi A4 Quattro. However, it is still accessible from the selected car via links, so may be relevant.

Install in reverse order of removal and Note The Following  :

TIP:

Batteries from the Audi Parts Program have a base strip adapter for conforming to different clamping strips. See the battery operating instructions for information on when and how to use the base strip adapter.

At vehicles using a central venting system hose, this hose needs to be inserted in the respective vent opening at the battery again. The vent opening on the opposing side must be closed with a blind plug.

-- Push the battery up to the stop on the retaining bracket -1- so that the battery clamping strip engages in the retaining bracket -arrow-.

GWWA27-10705Courtesy of AUDI OF AMERICA, LLC

-- Attach the central venting system hose.

Further installation is performed in reverse order of removal, while noting the following:

-- When the ignition and electrical equipment are switched off, connect the battery in the following sequence:

-- First connect the battery positive cable terminal clamp -2- to the battery positive terminal "+" by hand and tighten the nut -3-.

Fig 1: Battery Ground Cable Connector With Bolt
GWWA27-10537Courtesy of AUDI OF AMERICA, LLC

-- Close the cover -1- over the battery positive terminal.

-- Disconnect the connector -2- from the Battery Monitoring Control Module -J367- -3-.

Fig 2: Connecting Battery
GWWA27-10252Courtesy of AUDI OF AMERICA, LLC

-- Connect the battery ground cable terminal clamp to the battery negative terminal "-" by hand and tighten the nut -1-.

-- Reconnect the connector to the Battery Monitoring Control Module -J367-.

-- Check the battery for secure fit after installation.

-- Re-energize the 48V system. Refer to 48V SYSTEM, RE-ENERGIZING .

-- If the battery was replaced, then the new battery must be adapted.

Procedure 

-- Connect the Vehicle Diagnostic Tester.

-- Select the Diagnostic  mode and start the diagnosis.

-- Select the Test plan  tab.

-- Select the Select individual test  button and select the following tree structure consecutively:

-- Start the selected program and follow the instructions on the Vehicle Diagnostic Tester display.

When the battery is reconnected, the following steps must be performed:

TIP:

After reconnecting the power supply, the ESP warning lamp can only go out after the vehicle has been driven a few meters.