LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2020 >> S4 Prestige >> Repair and Diagnosis >> External Pages >> Different car >> Section 69 (Charging System (Battery, Starter And Generator) & Cruise Control (1 Of 2)) >> 27 Battery, Starter, Generator, Cruise Control >> Battery >> Battery, Disconnecting And Connecting >> Battery -A-, DISCONNECTING AND CONNECTING, 0K4 AND VH2 >> Connecting

Battery -A-, DISCONNECTING AND CONNECTING, 0K4 AND VH2: Connecting

WARNING: This page is about a different car, the 2021 Audi S4 and 2021 Audi A4 Quattro. However, it is still accessible from the selected car via links, so may be relevant.
Fig 1: Connecting Battery
GWWA27-10252Courtesy of AUDI OF AMERICA, LLC

-- Disconnect the connector -2- from the Battery Monitoring Control Module -J367- -3-.

-- Attach the battery ground cable clamp by hand to the battery negative terminal "-" and tighten the nut -1-.

-- Reconnect the connector to the Battery Monitoring Control Module -J367-.

-- Re-energize the 48V system. Refer to 48V SYSTEM, RE-ENERGIZING .

When the battery is reconnected, the following steps must be performed:

TIP:

After reconnecting the power supply, the ESP warning lamp can only go out after the vehicle has been driven a few meters.

Tightening Specifications