Possible Deviation From Specified Value During The Pressure Test (2 Of 11)
WARNING: This page is about a different car, the 2021 Audi S4 and 2021 Audi A4 Quattro. However, it is still accessible from the selected car via links, so may be relevant.
| Possible Deviation from Specified Value During the Pressure Test |
- The required cooling output is reached at first in the evaporator in the heater and A/C unit (and in the evaporator for battery cooling) after some time or after a longer running time the cooling output is no longer sufficient.
- The high pressure and low pressure are normal.
- After some time the high pressure raises above the specified value, the low pressure corresponds to the specified value or it falls under the specified value.
|
| Possible causes for the deviation from specified value and their solutions |
- Radiator for coolant, condenser is contaminated or the activation of the radiator fan is not OK.
-- Check the activation of the radiator fan and if necessary service. Use the Vehicle Diagnostic Tester in the"Guided Fault Finding"
function of the A/C system.-- Check the condenser and radiator for the condenser for contamination and if necessary clean. Refer to Refrigerant Circuit
and RADIATOR/RADIATOR FAN
.
- Activation of function of the A/C compressor (or if equipped the refrigerant shut-off valve 1 or the refrigerant shut-off valve 2) is faulty.
- Moisture in refrigerant circuit
-- Check the activation of the A/C compressor (and if equipped the refrigerant shut-off valve 1 and the refrigerant shut-off valve 2) and the measured value of the Evaporator Vent Temperature Sensor -G263-. Use the Vehicle Diagnostic Tester in the"Guided Fault Finding"
function.-- If the activation of the A/C compressor (and if equipped the refrigerant shut-off valve 1 and the refrigerant shut-off valve 2) as well as the measured value of the Evaporator Vent Temperature Sensor -G263- is OK extract the refrigerant from the refrigerant circuit. Refer to REFRIGERANT CIRCUIT, DISCHARGING
.
- Too much refrigerant in the refrigerant circuit
- Expansion valve malfunctioning
- If a shut-off valve installed in the refrigerant circuit does not open or opens incorrectly. Refer to Refrigerant Circuit
.
- Moisture in refrigerant circuit
-- Extract refrigerant from the refrigerant circuit. Refer to REFRIGERANT CIRCUIT, DISCHARGING
.-- If the extracted refrigerant quantity is substantially greater (more than 100 g (3.5 oz)) than the specified capacity there is too much refrigerant in the refrigerant circuit. Fill the refrigerant circuit and repeat the test. Refer to Technical Data
.-- If the extracted refrigerant quantity meets the specified capacity is only slightly greater than the specified capacity (maximum 100 g (3.5 oz)) too much refrigerant oil is in the refrigerant circuit. Refer to Technical Data
. Clean the refrigerant circuit (flush with refrigerant R1234yf) and fill with the correct quantity of refrigerant and refrigerant oil and repeat the test. Refer to REFRIGERANT CIRCUIT, CLEANING
.-- If equipped check the function of the installed shut-off valve. Refer to Refrigerant Circuit
.-- Replace the expansion valve and desiccant bag/dryer cartridge (or reservoir/receiver/dryer). Refer to COMPONENTS, REPLACING
and Refrigerant Circuit
. |
| Final Procedures |
| -- Charge the refrigerant circuit. Refer to REFRIGERANT CIRCUIT, CHARGING
.-- Repeat the test. Refer to ELECTRICALLY-DRIVEN A/C COMPRESSOR, CHECKING PRESSURE WITH A/C SYSTEM SWITCHED ON . |
NOTE:
If too much refrigerant oil is located in the circuit, the A/C compressor must be discharges and replace the receiver/receiver/dryer (or dryer cartridge). Refer to Refrigerant Circuit
. After cleaning the refrigerant circuit (flushing with refrigerant R1234yf) fill it with the correct quantity of refrigerant oil in the refrigerant circuit. Refer to REFRIGERANT CIRCUIT, CLEANING
and Technical Data
.
Check the measured values of the Evaporator Vent Temperature Sensor -G263- and the activation of the A/C compressor. If the measured value of the Evaporator Vent Temperature Sensor -G263- or the activation of the A/C compressor is faulty, the evaporator can freeze-up or the cooling output is not reached. Use the Vehicle Diagnostic Tester in the"Guided Fault Finding"
function for the A/C system and the battery regulation. Refer to Component Location Overview - A/C System
and A/C Compressor
.
With this malfunction, evaporator may ice up although the quantity of refrigerant in circuit is OK.
Likewise, the refrigerant circuit may become iced if there is a malfunction on the Evaporator Vent Temperature Sensor -G263- or/and on the temperature sensor after hybrid battery evaporator. For this concern also pay attention to the measured value of the Evaporator Vent Temperature Sensor -G263- and the temperature sensor after hybrid battery evaporator (on vehicles with battery cooling module). Use the Vehicle Diagnostic Tester in the"Guided Fault Finding"
function of the A/C system and the battery regulation. Refer to Component Location Overview - A/C System
.