LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2020 >> Q5 Premium Plus >> Repair and Diagnosis >> External Pages >> Different car >> Section 51 (Seat Frames) >> 72 Seat Frames >> Front Seat Pneumatic System >> Pneumatic System, Checking >> Driver And Front Passenger Multi-Contour Seat Compressor -V439- / -V440- And Pressure Line, Preparations For Leak Check

Driver And Front Passenger Multi-Contour Seat Compressor -V439- / -V440- And Pressure Line, Preparations For Leak Check

WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2022 Audi SQ5, 2022 Audi Q5 e, 2022 Audi Q5, 2021 Audi SQ5, and 2021 Audi Q5 e. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:

When an appropriate entry is made in the event memory, there is a prompt in "Guided Fault Finding" to perform a leak check using the Vehicle Diagnostic Tester.

Then the preparations for this leak test are described that must be carried out directly in the seat.

Connection diagram with assignment of the pneumatic lines to the air cushions. Refer to CONNECTION DIAGRAM - PNEUMATIC SYSTEM .

Special tools and workshop equipment required 

Procedure 

In one of the test steps in the "Guided Fault Finding", there is a prompt to connect the :VAG1397A  at the pneumatic line from the -V439- / -V440-.

-- Disconnect the pneumatic line -1- to the -V439- / -V440- at the marking -arrow-. Refer to PNEUMATIC LINES, DISCONNECTING AND CONNECTING .

GWWA72-12589Courtesy of AUDI OF AMERICA, LLC

-- Using hoses and connectors from the :VAS6618  , connect the :VAG1397A  with the pneumatic line -1- coming from the compressor.

GWWA72-12610Courtesy of AUDI OF AMERICA, LLC
NOTE:

To connect, insert the pneumatic lines into the :VAS6618/3  from both sides -A arrows-.

Fig 1: Attach The Connecting Sleeves
GWWA72-11372Courtesy of AUDI OF AMERICA, LLC

To release, push the release rings -B arrows- and simultaneously remove pneumatic lines -C arrows-.

In one of the test steps in the "Guided Fault Finding", there is a prompt to connect the :VAG1397A  directly to the compressor.

-- Disconnect the pneumatic line -1- from the compressor -2- at the marking -arrow-. Refer to PNEUMATIC LINES, DISCONNECTING AND CONNECTING .

GWWA72-12611Courtesy of AUDI OF AMERICA, LLC

-- Using the hose and connectors from the :VAS6618  , connect the :VAG1397A  with the pneumatic line -1- for the compressor -2-.

GWWA72-12612Courtesy of AUDI OF AMERICA, LLC

-- Connect the pneumatic lines following the leak test. Refer to PNEUMATIC LINES, DISCONNECTING AND CONNECTING .