Plenum Chamber Bulkhead, Removing And Installing: Removing
-- Remove the engine cover. Refer to ENGINE COVER, REMOVING AND INSTALLING .
-- For vehicles that have a pass-through for the coolant lines through the plenum chamber bulkhead, drain the coolant. Refer to COOLANT, DRAINING AND FILLING .
-- Remove the plenum chamber cover. Refer to PLENUM CHAMBER COVER, REMOVING AND INSTALLING .
Q5 with High-Voltage System:
High voltage increases the risk of fatal injury
Electrocution can cause severe bodily or fatal injury.
- Have an Audi high-voltage technician (HVT) or an Audi high-voltage expert (HVE) de-energize the high-voltage system.
-- De-energize the high-voltage system. Refer to appropriate service information. .
-- Free up the High-Voltage Cable for High-Voltage Heater (PTC) -P11- -1- and remove the pass-through -2-.
-- Disconnect the high-voltage cable on the high-voltage heater -3-.
-- To do so remove the connector lock -3- in direction of -arrow A-.
-- Press the release -4- in the direction of the -arrow B- and remove the connector -1- approximately 5 mm up to the next release level.
-- Press the release -5- in the direction of the -arrow D- and remove the connector from the connector mount -2- in direction of -arrow C-.
- The high-voltage wiring harness must be replaced if the connector is damaged.
Continuation:
-- Remove the tower brace. Refer to TOWER BRACE, REMOVING AND INSTALLING .
-- Remove the nuts -arrows- and remove the bracket -1- with the Relay and Fuse Panel 3 -SR3-.
-- Pry up the clamps -1 and 5- and remove the coolant hoses.
-- Loosen the hose clamps -3-, remove the coolant hoses -2 and 4- and free them up.
-- Remove the nuts -arrows-.
-- Remove the plenum chamber bulkhead -1- upward.
-- Release the catch in direction of -arrow-, disengage the pass-through -1- on the plenum chamber bulkhead -2- and remove.