LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2020 >> Q5 Premium Plus >> Repair and Diagnosis >> External Pages >> Different car >> Section 26 (Air Conditioning (Refrigerant R1234YF Servicing) (Tools & Testing Equipment)) >> 87 Air Conditioning >> Working With A/C Service Station >> Contaminated Refrigerant, Filling In Recycling Container For Analysis, Processing, Or Disposal >> RECYCLING CONTAINER, FILLING WITH CONTAMINATED REFRIGERANT USING Extraction Unit:VAS581011

RECYCLING CONTAINER, FILLING WITH CONTAMINATED REFRIGERANT USING Extraction Unit:VAS581011

WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2022 Audi SQ5, 2022 Audi Q5 e, 2022 Audi Q5, 2021 Audi SQ5, and 2021 Audi Q5 e. However, it is still accessible from the selected car via links, so may be relevant.

Special tools and workshop equipment required 

Procedure 

-- Connect the Extraction Unit:VAS581011  according to the included Owner's Literature with the vehicle and the A/C Service Station R1234yf.

-- Fill the contaminated refrigerant using the Extraction Unit:VAS581011  in the recycling container. Refer to the Owner's Literature.

-- Fill out the supplement data sheet for the recycling bottle with contaminated refrigerant and secure on the recycling bottle.

-- Return the filled recycling bottle using the method of delivery for the recycling bottle, while paying attention to the applicable laws.

-- Evacuate the refrigerant circuit with the A/C Service Station for at least one hour. Refer to REFRIGERANT CIRCUIT, EVACUATING .