High Pressure Sensor -G65-, REMOVING AND INSTALLING: Removing

WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2022 Audi SQ5, 2022 Audi Q5 e, 2022 Audi Q5, 2021 Audi SQ5, and 2021 Audi Q5 e. However, it is still accessible from the selected car via links, so may be relevant.

-- Switch off the ignition.

Q5

-- Remove the upper radiator shutter. Refer to RADIATOR SHUTTER, REMOVING AND INSTALLING .

Continuation for all additional vehicles

-- Remove the cover on the lock carrier. Refer to LOCK CARRIER COVER, REMOVING AND INSTALLING .

-- Disconnect the connector -D-.

GWWA87-12095Courtesy of AUDI OF AMERICA, LLC
CAUTION:

Danger or frostbite due to refrigerant coming out under pressure.

Frostbite on the skin and other parts of the body is possible.

- Wear safety gloves.

- Wear protective eyewear.

- If refrigerant flows out of the refrigerant line longer than 1 second when loosening the pressure sensor, tighten the pressure sensor and replace the faulty check valve.

- Evacuate or drain refrigerant and open the refrigerant circuit immediately.

- If more than 10 minutes elapse after extracting or draining the refrigerant and the refrigerant circuit was not opened, extract or drain the refrigerant again. Pressure develops in the refrigerant circuit due to evaporation.

-- Remove the High Pressure Sensor -G65- -A- from the connection on the condenser -C-.