LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2020 >> Q5 Premium Plus >> Repair and Diagnosis >> External Pages >> Different car >> Section 13 (Communication) >> 91 Communication >> Rearview Camera System >> Rearview Camera System, Calibrating >> Calibration Unit:VAS6350A, INSTALLING AND ALIGNING >> Installed Overview

Installed Overview

WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2022 Audi SQ5, 2022 Audi Q5 e, 2022 Audi Q5, 2021 Audi SQ5, and 2021 Audi Q5 e. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:

The vehicle in the illustration is only a basic outline.

Fig 1: Identifying Overview Of Assembled Calibration Equipment
GWWA91-10524Courtesy of AUDI OF AMERICA, LLC
  1. :VAS6350/1 
  2. :VAS6350/1 
  3. Right Angle Bracket
    • :VAS6350/2  mount
  4. Plastic Foot
    • Three on underside of the calibration board
    • Adjustable for aligning horizontal position of the calibration board
  5. :VAS6350/3 
    • On the calibration board
    • Switching on and off. Refer to the Owner's Literature.
  6. :VAS6350/2 
    • On the calibration board
    • Refer to the Owner's Literature for notes on the operation.
  7. Level
    • On the calibration board
    • For checking the horizontal position
  8. Left Angle Bracket
    • :VAS6350/2  mount
  9. Calibration Board
    • Between the mounts on the calibration board and the :VAS6350/1  -dimension A- 1.47 m through 1.90 m

Calibration Board Orientation

-- Position the calibration platform behind the vehicle at a distance of 1.47 m to 1.90 m to the rear wheels, see -dimension A- in the overview illustration. Refer to Installed Overview .

-- Bring the :VAS6350A  into a horizontal position.

-- Twist the plastic feet under the calibration board so that the air bubble in the level is located exactly in the center of the indicator -arrow-.

Fig 2: Identifying Bubble Level (Sight Glass) On Calibration Tool VAS 6350
GWWN94-10686Courtesy of AUDI OF AMERICA, LLC
WARNING:

Make sure light does not reflect off the calibration board.

Reflections impair the Rearview Camera -R189- and may make it impossible to perform the calibration.

NOTE:

The vehicle in the illustration is only a basic outline.

Fig 3: Identifying Laser -1- On Calibration Platform Set To Align Entire Calibration Platform With Vehicle
GWWA91-10525Courtesy of AUDI OF AMERICA, LLC

-- Switch on the :VAS6350/3  -1- on the calibration board and adjust the entire :VAS6350A  so that the laser beam hits the center of vehicle rear above the Audi rings.

-- Check that the Audi rings are centered on the rear. Correct the laser beam accordingly.

Continue calibrating the Rearview Camera -R189-. Refer to Rearview Camera -R189-, CALIBRATING .