LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2020 >> Q5 Premium Plus >> Repair and Diagnosis >> Body & Frame >> Door Locks >> Interior Lights, Switches >> 96 Interior Lights, Switches >> Lane Change Assistance >> Lane Change Assistance, Calibrating

Lane Change Assistance, Calibrating

Special tools and workshop equipment required 

Conditions

-- The Lane Change Assistance Control Module -J769- / Lane Change Assistance Control Module 2 -J770- must be calibrated using the Vehicle Diagnostic Tester during the following conditions:

Preparing for Calibration

GWWA96-11470Courtesy of AUDI OF AMERICA, LLC
  1. Calibration Tool - Spacing Laser: VAS 6350/2 
    • For distance measurement
    • Usage information. Refer to the Calibration Tool: VAS 6350  Owner's Manual.
  2. Calibration Unit: VAS6350A 
  3. Level
    • On the Calibration Tool: VAS6350A 
    • For checking the horizontal position of the Calibration Tool: VAS6350A 
  4. Catch Bracket
    • To mount the Calibration Tool - Spacing Laser -VAS6350/2- for the distance measurement
    • Distance to the Calibration Tool - Wheel Center Mountings -VAS6350/1- on the rear wheels: dimension -a- = 1700 ± 2 mm
  5. Calibration Tool - Lane Change Calibration Tool: VAS6350/4 
    • Is moved from one side of the measuring field to the other during calibration
    • When installed correctly, the vehicle electrical system voltage line must be connected at lower left of the calibration device (as seen in direction of travel)
  6. Brand Emblem
    • The laser point is aligned to the center of the brand emblem
  7. Calibration Tool - Wheel Center Mountings: VAS6350/1 
    • With wheel bolt adapter and measuring paddle
  8. Measuring Scale
    • For positioning the Calibration Tool - Lane Change Calibration Tool: VAS6350/4 
  9. Calibration Tool - Linear Laser: VAS6350/3A 
    • With "laser protective eyewear"
    • On the Calibration Tool: VAS6350A 
    • Turning on and off. Refer to the Calibration Tool: VAS 6350  Operating Instructions.
  10. Plastic Foot
    • Can be adjusted when setting the horizontal position of the Calibration Tool: VAS6350A 
    • Quantity: 3

Preliminary Work

-- Move the vehicle onto a solid, flat surface.

-- Activate the "standard vehicle height" on vehicles with air suspension (MMI setting: automatic or comfort).

-- Apply the parking brake - the vehicle must not move during the measurement.

-- Place the front wheels in a straight-ahead position - steering wheel in neutral position.

-- Connect the Vehicle Diagnostic Tester.

TIP:

If a malfunction message appears in the display, refer to the Vehicle Diagnostic Tester.

-- Switch the ignition on.

-- Remove the label with the metal foil from the bumper cover, if necessary.

-- Secure three suitable wheel bolt adapters for the wheel bolts on each Calibration Tool - Wheel Center Mountings -VAS6350/1-.

Fig 1: Identifying Wheel Pick-Ups On Wheel Mounting Bolts At Rear Wheels
GWWN94-10685Courtesy of AUDI OF AMERICA, LLC

-- Insert the measuring paddle at both Calibration Tool - Wheel Center Mountings -VAS6350/1- and secure with the locking nut.

-- Place the Calibration Tool - Wheel Center Mountings -VAS6350/1- onto the wheel bolts on both rear wheels.

-- Place the Calibration Tool - Wheel Center Mountings -VAS6350/1- on the wheels so that the "anti-theft wheel bolts" are not connected to the wheel center mounting.

-- Adjust the measuring paddle using the locking nuts so that they move freely just above the floor.

-- Position the Calibration Tool: VAS6350A  at distance -a- to the rear wheels.

Fig 2: Positioning Calibration Device VAS 6350
GWWA96-10536Courtesy of AUDI OF AMERICA, LLC

-- Switch on the Calibration Tool - Spacing Laser: VAS6350/2  with the ON  button.

Fig 3: Identifying Laser Display
GWWN94-10681Courtesy of AUDI OF AMERICA, LLC

Display on the Calibration Tool - Spacing Laser: VAS6350/2A  :

-- For distance measurement, hold the Calibration Tool - Spacing Laser: VAS6350/2  -2- flush to the left catch bracket as shown.

Fig 4: Holding Distance Laser VAS 6350/2 Flush To Catch Bracket
GWWA96-10535Courtesy of AUDI OF AMERICA, LLC

-- Make sure the "laser beam" for the distance measurement contacts the enlarged lower part on the paddle -1-.

If this is not the case, measuring paddle height must be corrected using locking nuts on Wheel Center Mounting -VAS6350/1-.

-- Briefly press the ON  button for distance measurement.

Fig 5: Identifying Display On VAS 6350/2
GWWA96-10289Courtesy of AUDI OF AMERICA, LLC

Display on the Calibration Tool - Spacing Laser: VAS 6350/2A  :

-- Repeat the measuring procedure from the right stop bracket to the right rear wheel.

If both measured values are not the same, adjust the Calibration Tool: VAS6350A  accordingly.

Calibrating Procedure

The Vehicle Diagnostic Tester is connected.

-- Select and start the Diagnostic  operating mode.

-- Select the Test plan  tab.

-- Select the Select individual test  button and select the following tree structure consecutively:

-- Start the selected program and follow the instructions on the Vehicle Diagnostic Tester display.

TIP:

-- Secure the Calibration Tool - Lane Change Calibration Tool -VAS6350/4- to the mount for the Calibration Tool: VAS6350  at the rear left.

GWWA96-11376Courtesy of AUDI OF AMERICA, LLC

Dimension -a- is measured from the upper edge of the calibration device to the floor.

Model Q5, all versions
Adjustment dimension height in mm dimension -a- 602

-- The indicator on the base of the Calibration Tool - Lane Change Calibration Tool -VAS6350/4- must align with the adjustment dimension on the measuring scale -1- on the measuring field -arrow-.

Model Q5, all versions
Left adjustment dimension read in mm on the measuring scale -1- 770

-- Connect the Calibration Tool - Lane Change Calibration Tool -VAS6350/4- to the vehicle electrical system voltage.

-- Bring Calibration Tool: VAS6350  into horizontal position by turning the plastic feet.

Fig 6: Identifying Bubble Level (Sight Glass) On Calibration Tool VAS 6350
GWWN94-10686Courtesy of AUDI OF AMERICA, LLC

-- Turn on the Calibration Tool - Linear Laser -VAS6350/3A- on the Calibration Unit: VAS6350A  .

GWWA96-11453Courtesy of AUDI OF AMERICA, LLC

-- Wear "laser protective eyewear".

-- Align the Calibration Tool: VAS6350A  so that the Calibration Tool - Linear Laser -VAS6350/3A- strikes the center of the brand emblem on the rear lid.

-- Check the distance on the left and right sides between the catch brackets of the Calibration Unit: VAS6350A  and the measuring paddles -1- on wheel mountings again.

Fig 7: Holding Distance Laser VAS 6350/2 Flush To Catch Bracket
GWWA96-10535Courtesy of AUDI OF AMERICA, LLC

Calibration Procedure

The following should not occur during the calibration procedure:

Procedure 

Fig 8: Identifying Assistance Calibration Device VAS 6350/4 Components
GWWA96-10358Courtesy of AUDI OF AMERICA, LLC

-- Turn on the Calibration Tool - Lane Change Calibration Tool -VAS6350/4- at the voltage switch -3-.

-- The red LED -2- is illuminated: check the Calibration Tool - Lane Change Calibration Tool -VAS6350/4-.

-- Follow the instructions in the vehicle diagnostic tester display.

During the program sequence, there is a prompt to switch the Calibration Tool - Lane Change Calibration Tool -VAS6350/4- from the left to the right side of the Calibration Tool: VAS6350  .

GWWA96-11375Courtesy of AUDI OF AMERICA, LLC

-- Turn off the Calibration Tool - Lane Change Calibration Tool -VAS6350/4- and reposition the calibration tool.

Dimension -a- is measured from the upper edge of the calibration device to the floor.

Model Q5, all versions
Adjustment dimension height in mm dimension -a- 602

-- The indicator on the base of the Calibration Tool - Lane Change Calibration Tool -VAS6350/4- must align with the adjustment dimension on the measuring scale -1- on the measuring field -arrow-.

Model Q5, all versions
Right adjustment dimension read in mm on the measuring scale -1- 770

-- Turn on the Calibration Tool - Lane Change Calibration Tool -VAS6350/4- at the voltage switch -3-.

Fig 9: Identifying Assistance Calibration Device VAS 6350/4 Components
GWWA96-10358Courtesy of AUDI OF AMERICA, LLC

-- Follow the instructions in the vehicle diagnostic tester display.

-- After calibrating the lane change assistance successfully, end "calibration", switch off the ignition and disconnect the diagnostic connector.