Refrigerant Lines, Disconnecting From Front Expansion Valve And Reconnecting: Notes
Special Tools And Workshop Equipment Required
- Engine Bung Set :VAS6122
This procedure contains mandatory replaceable parts. Refer to component overview and Parts Information prior to starting procedure.
Mandatory Replacement Parts
- O-ring - Service Connection - Low Pressure Side to Front Expansion Valve
- O-ring - Refrigerant Line - High Pressure Side to Front Expansion Valve
After switching off the A/C compressor in this vehicle, it may take a relatively long time for the pressure on the high pressure side to decrease. This is because the expansion valve is cold and the pressure on the low pressure side increases quickly after shutting the compressor off, then the expansion valve closes and the refrigerant flows slowly to the low pressure side.
Certain tools are required to discharge the refrigerant circuit. These work procedures may only be performed by trained personnel. Refer to A/C SYSTEM, GENERAL INFORMATION or LAWS AND REGULATIONS [R1234yf] / LAWS AND REGULATIONS [R134a] .