Refrigerant Lines, Disconnecting From Front Expansion Valve And Reconnecting: Installing
Install in reverse order of removal and Note The Following:
-- Check the support ring -G- for proper installation position and check the grommet in the plenum chamber rear panel for damage and proper installation.
-- Thoroughly clean all connections in expansion valve -D- and at refrigerant lines -B and C- and check for damage.
-- Replace the O-ring seals -E and F-. Refer to the Parts Information for the correct version.
Follow the instructions for installing the O-rings. Refer to REFRIGERANT CIRCUIT SEALS .
-- Coat the O-ring seals lightly with refrigerant oil before installing. Refer to REFRIGERANT CIRCUIT SEALS .
-- Make sure the O-ring seals fit properly inside the grooves in the connections of refrigerant lines -B and C-.
-- Tighten the nut -A- for the refrigerant lines -B and C-.
-- Check the routing of the refrigerant lines after attachment. They must be inserted in the provided brackets in a tension-free manner and must not come in contact with other components.
-- Evacuate and fill the refrigerant circuit. Refer to REFRIGERANT CIRCUIT, EVACUATING WITH A/C SERVICE STATION [R134a] /REFRIGERANT CIRCUIT, CHARGING WITH A/C SERVICE STATION [R134a] or REFRIGERANT CIRCUIT, EVACUATING [R1234yf] / REFRIGERANT CIRCUIT, CHARGING [R1234yf] .
-- Install the remaining removed components.
-- Retrieve the Front A/C Display Control Head -E87- DTC memory and if necessary delete the displayed error using the Vehicle Diagnostic Tester in the "Guided Fault Finding" function.
-- Operate the A/C system after charging the refrigerant circuit. Refer to A/C SYSTEM, STARTING AFTER CHARGING REFRIGERANT CIRCUIT .
Read the information for starting the A/C system after filling. Refer to A/C SYSTEM, GENERAL INFORMATION or A/C SYSTEM, OPERATING AFTER CHARGING [R1234yf] .