Charge Air System, Checking For Leaks
Special tools and workshop equipment required
- Turbo System Tester Kit - Adapter 10:VAG1687/10
- Turbo System Tester Kit - Adapter:VAG1687/14
- Turbo System Tester Kit:VAG1687
Procedure
-- Loosen the hose clamps -1 and 2- and remove the air duct pipe.
-- Connect the :VAG1687/10 with the :VAG1687/14 to the turbocharger.
-- Connect the :VAG1687 to the adapter.
All additional procedures are described. Refer to CHARGE AIR SYSTEM, CHECKING FOR LEAKS .
Assembling
Assemble in the reverse order of removal. Note the following:
- Secure all hose connections with hose clamps that match the ones used in series production. Refer to the appropriate service information.
Tightening Specifications
- Refer to OVERVIEW - CHARGE AIR HOSE CONNECTIONS .