Overview - Cylinder Block, Belt Pulley Side, Vehicles With Generator
WARNING: This page is about a different variant/trim than selected.
- Ribbed Belt
- Check for wear
- Do not kink
- Before removing, mark the running direction using chalk or a felt-tip pen.
- Removing and installing. Refer to RIBBED BELT, REMOVING AND INSTALLING .
- Ribbed belt routing. Refer to Fig 2.
- When installing, make sure it is seated correctly on the belt pulleys
- Ribbed Belt Tensioner
- To release tension on ribbed belt, pivot using a wrench.
- Secure using the Locking Pin: T10060 A
- Removing and Installing. Refer to RIBBED BELT TENSIONER, REMOVING AND INSTALLING .
- Bolt
- 8 Nm + 45°
- Always replace after removing.
- Bolt
- 150 Nm + 90°
- Always replace after removing.
- Coat the O-ring with engine oil
- Use the Counterhold - Vibration Damper: T10355A to loosen and tighten
- O-Ring
- Not a replacement part; supplied with bolt - ) OVERVIEW - CYLINDER BLOCK, BELT PULLEY SIDE, VEHICLES WITH GENERATOR - List Item: Bolt
- Vibration Damper
- With the ribbed belt pulley
- Removing and Installing. Refer to VIBRATION DAMPER, REMOVING AND INSTALLING .
- Sub-Assembly Bracket
- With oil filter and engine oil cooler
- Removing and installing the sub-assembly bracket. Refer to SUB-ASSEMBLY BRACKET, REMOVING AND INSTALLING .
- Removing and installing the engine oil cooler. Refer to ENGINE OIL COOLER, REMOVING AND INSTALLING .
- Seal
- Always replace after removing.
- Bolt
- Tightening Specifications and Sequence. Refer to Fig 3.
- Always replace after removing.
- Bolt
- Tightening specifications. Refer to OVERVIEW - GENERATOR .
- Generator
- Removing and installing. Refer to GENERATOR, REMOVING AND INSTALLING .
- Alignment Sleeves
- For the A/C compressor
- A/C Compressor
- Do not remove or disconnect the refrigerant lines
- Removing and Installing. Refer to A/C COMPRESSOR, REMOVING AND INSTALLING FROM BRACKET .
- Bolt
- Tightening specifications. Refer to OVERVIEW - A/C COMPRESSOR POWER UNIT .
Ribbed Belt Routing
- Vibration Damper
- Ribbed Belt Tensioner
- Generator
- A/C Compressor
Sub-Assembly Bracket - Tightening Specifications and Sequence
- Replace the bolts that were tightened with an additional turn after removing them.
-- Mount the sub-assembly bracket and then install the bolts -4- first.
-- Tighten the bolts in the steps shown in the sequence:
| Step | Bolts | Tightening Specification/Additional Turn |
|---|---|---|
| 1. | -1 through 5- | Install by hand all the way |
| 2. | -1 through 5- | 20 Nm |
| 3. | -1 through 5- | 90° additional turn |