Charge Air System, Checking For Leaks: Notes
Special Tools And Workshop Equipment Required
- Turbo System Tester Kit:VAG1687
- Ultrasonic Tester:VAG1842S
Depending on the model, preliminary work may be required. Refer to CHARGE AIR SYSTEM .
Prepare the :VAG1687 as follows:
-- Completely remove the pressure regulating valve -2- and close the valves -3 and 4-.
- Pull the knob in order to rotate the pressure regulating valve -2-.
-- Connect the :VAG1687 to compressed air -1- with a commercially available intermediate piece.
-- Drain the water in the viewing glass via the water drain plug -6-.
-- Open the valve -3-.
There is a risk of damage if the pressure is set too high.
- Pressure must not exceed 0.2 bar (2.9 psi)!
-- Set the pressure to 0.2 bar (2.9 psi) using the pressure regulating valve -2-.
-- Open the valve -4- and wait until the test circuit is filled. Regulate the pressure to 0.2 bar (2.9 psi) again if necessary.
-- Listen, feel and use commercially available leak detection spray or the :VAG1842 to check the charge air system for leaks.
A small quantity of air dissipates via the valves in the engine. For this reason a pressure retention test is not possible.
Information on the :VAG1842S . Refer to the Operating Instructions.
Release the pressure in the test circuit by pulling off the coupling before removing the adapter.
Secure all hose connections with hose clamps that match the ones used in series production. Refer to the Parts Information.