Service Connection On Low And High Pressure Side, Removing And Installing: Removing
-- Remove the sealing caps (with seal) -1 or 2-.
-- Discharge the refrigerant circuit. Refer to Refrigerant Circuit (Refrigerant R134a Servicing, Refrigerant Circuit, Working with A/C Service Station) or Working with A/C Service Station (1 Of 2) / Working with A/C Service Station (2 Of 2) .
WARNING:
Danger due to refrigerant coming out under pressure.
Danger of frost bite to skin and other parts of the body.
- Evacuate the refrigerant and immediately open the refrigerant circuit afterward.
- If more than 10 minutes have elapsed since evacuating the refrigerant and the refrigerant circuit was not opened, evacuate the refrigerant again. Pressure in the refrigerant circuit is caused by evaporation.
-- Remove the service connection -3- using the :T10364 and a suitable adapter.
NOTE:
Additional information about the service connection. Refer to SERVICE CONNECTION DIFFERENCES, DEPENDING ON REFRIGERANT (R134A OR R1234YF) , A/C SYSTEM, GENERAL INFORMATION or GENERAL DESCRIPTION - REFRIGERANT CIRCUIT COMPONENTS .