Dryer Cartridge, Removing And Installing, MODINE Condenser: Removing
Remove the condenser until the dryer cartridge closure is reachable without loosening the respective refrigerant lines on the condenser. Refer to CONDENSER, REMOVING AND INSTALLING .
Condenser Version "1" :
-- Remove the safety warning label (if equipped).
-- Remove the closure cap -1-.
-- Check the refrigerant circuit pressure with the pressure gauge on an A/C service station. Refer to Refrigerant Circuit (Refrigerant R134a Servicing, Refrigerant Circuit, Working with A/C Service Station) or Working with A/C Service Station (1 Of 2) / Working with A/C Service Station (2 Of 2) .
Danger due to refrigerant coming out under pressure.
Danger of frost bite to skin and other parts of the body.
- Evacuate the refrigerant and immediately open the refrigerant circuit afterward.
- If more than 10 minutes have elapsed since evacuating the refrigerant and the refrigerant circuit was not opened, evacuate the refrigerant again. Pressure in the refrigerant circuit is caused by evaporation.
-- Push the closure cap -1- in slightly.
-- Remove the circlip -arrow- and then remove the closure cap from the condenser -2- using a M12 bolt.
-- Make a 2 mm welding wire with the following dimensions.
- Dimension -a- = 380 mm.
- Dimension -b- = maximum 7 mm.
- Dimension -c- = maximum 6 mm.
-- Hook the welding wire on the screen exactly as illustrated to prevent damage to the condenser.
-- Carefully remove the filter element (screen) -2- from the receiver/dryer using the welding wire -1-.
-- Seal the open receiver/dryer with the closure cap -1- to prevent dirt and moisture from getting in.
Condenser Version "2" :
-- Remove the protective cap -1- using the :T10128 .
-- Check the refrigerant circuit pressure with the pressure gauge on an A/C service station. Refer to Refrigerant Circuit (Refrigerant R134a Servicing, Refrigerant Circuit, Working with A/C Service Station) or Working with A/C Service Station (1 Of 2) / Working with A/C Service Station (2 Of 2) .
Danger due to refrigerant coming out under pressure.
Danger of frost bite to skin and other parts of the body.
- Evacuate the refrigerant and immediately open the refrigerant circuit afterward.
- If more than 10 minutes have elapsed since evacuating the refrigerant and the refrigerant circuit was not opened, evacuate the refrigerant again. Pressure in the refrigerant circuit is caused by evaporation.
-- Push the closure cap -1- in slightly.
-- Remove the circlip -arrow- and then remove the closure cap from the condenser -2- using a M12 bolt.
-- Remove the dryer unit -1- from the condenser -2- using needle nose pliers.
-- Seal the open receiver/dryer with the closure cap to prevent dirt and moisture from getting in.