A/C Pressure/Temperature Sensor -G395-, Removing And Installing: Removing
-- Discharge the refrigerant circuit. Refer to Refrigerant Circuit (Refrigerant R134a Servicing, Refrigerant Circuit, Working with A/C Service Station) or Working with A/C Service Station (1 Of 2) / Working with A/C Service Station (2 Of 2) .
-- Remove the front bumper cover. Refer to Front Bumper (Overview - Front Bumper).
-- Disconnect the connector -2-.
-- Check the refrigerant line and connection -4- for contamination and if necessary clean.
If due to the restricted installed dimension the connector -2- cannot be disconnected or the sensor -1- cannot be loosened or removed, remove the refrigerant line from the condenser. Refer to REFRIGERANT LINES, DISCONNECTING AND CONNECTING AT CONDENSER .
Remove the A/C Pressure/Temperature Sensor - G395- -1- only when the refrigerant circuit is empty; the connection -4- does not have a valve.
Danger due to refrigerant coming out under pressure.
Danger of frost bite to skin and other parts of the body.
- Evacuate the refrigerant and immediately open the refrigerant circuit afterward.
- If more than 10 minutes have elapsed since evacuating the refrigerant and the refrigerant circuit was not opened, evacuate the refrigerant again. Pressure in the refrigerant circuit is caused by evaporation.
-- Loosen and remove the sensor -1-.
-- Seal the open connection -4- with clean plugs from the :VAS6122 .