LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2018 >> A6 Premium Plus >> Repair and Diagnosis >> External Pages >> Different car >> Section 121 (Hybrid Control System (Diagnostic Codes (P0C73-776 - U0424-537) & Circuit Tests))) >> Hybrid Control System >> DTC P324E-788: MG-ECU Power Relay Intermittent Circuit [08/2013 - ] >> Procedure

DTC P324E-788: MG-ECU Power Relay Intermittent Circuit [08/2013 - ]: Procedure

WARNING: This page is about a different car, the 2014 Lexus ES 300h. However, it is still accessible from the selected car via links, so may be relevant.
  1. CHECK DTC OUTPUT (HYBRID CONTROL) 
    1. Connect the Techstream to the DLC3.
    2. Turn the power switch on (IG).
    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
    4. Check for DTCs.

      Result

      Result Proceed to
      P324E-788 only is output. A
      U0110-159, 160, 656, 657 are also output. B
    5. Turn the power switch off.

    B → See step   4 

    A: Go to next step 

  2. CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR). Refer to  PROCEDURE - Step 4 

    NG → CONNECT SECURELY 

    OK: Go to next step 

  3. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - IGCT RELAY) 
    WARNING:

    Be sure to wear insulated gloves.

    1. Check that the service plug grip is not installed.
      NOTE:

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the service information because this may cause a malfunction.

    2. Disconnect the A14 inverter with converter assembly connector.
    3. Remove the IGCT relay from the No. 2 engine room relay block.
    4. Measure the resistance according to the value(s) in the table below.
      GTY318913Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      TEXT IN ILLUSTRATION

      *1 No. 2 Engine Room Relay Block *2 IGCT Relay
      *a Front view of wire harness connector
      (to Inverter with Converter Assembly)
      - -

      Standard Resistance

      Tester Connection Condition Specified Condition
      A14-30 (+B) - 5 (IGCT relay) Power switch off Below 1 Ω
      A14-31 (+B2) - 5 (IGCT relay) Power switch off Below 1 Ω
      A14-10 (GND1) - Body ground Power switch off Below 1 Ω
      A14-11 (GND2) - Body ground Power switch off Below 1 Ω
    5. Install the IGCT relay.
    6. Reconnect the A14 inverter with converter assembly connector.

    NG → REPAIR OR REPLACE HARNESS OR CONNECTOR 

    OK → See step   5 

  4. GO TO DTC CHART (HYBRID CONTROL SYSTEM). Refer to  DIAGNOSTIC TROUBLE CODE CHART [08/2013 - ] 
  5. REPLACE INVERTER WITH CONVERTER ASSEMBLY. Refer to  COMPONENTS [08/2013 - ]