Home >> Audi >> 2017 >> TT Quattro Base, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 54 (Charging System (Battery, Starter, Generator) & Cruise Control (2 Of 2) [Coupe]) >> 27 Starter, Generator And Cruise Control >> Battery, Checking >> Test Sequence >> CHECKING THE BATTERY - VEHICLES WITHOUT A Battery Monitoring Control Module -J367- OR Energy Management Control Module -J644-

CHECKING THE BATTERY - VEHICLES WITHOUT A Battery Monitoring Control Module -J367- OR Energy Management Control Module -J644-

WARNING: This page is about a different variant/trim than selected.
CAUTION:

It is not possible to check the battery using "Guided Fault Finding  " through MY 2010 during the following procedure, even if the vehicle has a Battery Monitoring Control Module -J367- :

  • A3 from MY 2004 (8P)
  • TT from MY 2007 (8J)
  • R8 from My 2007 (42)
WARNING:

Risk of injury. Follow all warning messages and safety precautions. Refer to WARNINGS AND SAFETY PRECAUTIONS .

Perform the Tests in the Following Sequence: 

-- Visual inspection. Refer to VISUAL INSPECTION .

-- Check the visual indicator color display (if equipped). Refer to VISUAL INDICATOR COLOR DISPLAY, CHECKING .

WARNING:

Do not check or charge a Battery -A- when the visual indicator has >>no color or is bright yellow<<. Jump starting must not be used!

There is a risk of explosion during testing, charging or jump starting.

These Batteries -A- must be replaced.

NOTE:

The :VAS5097A  will no longer be used for warranty testing. Only the :VAS6161  is still being used.

-- Battery test with:

-- Depending on the result of the battery load test, "perform current draw test". Refer to CURRENT DRAW TEST .