LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2017 >> TT Quattro Base, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 54 (Charging System (Battery, Starter, Generator) & Cruise Control (2 Of 2) [Coupe]) >> 27 Starter, Generator And Cruise Control >> Battery, Charging >> Solar Battery Maintainer :VAS6102A >> Solar Battery Maintainer :VAS610A MAINTENANCE CHARGING

Solar Battery Maintainer :VAS610A MAINTENANCE CHARGING

WARNING: This page is about a different variant/trim than selected.

Special tools and workshop equipment required 

Procedure 

-- Secure the :VAS6102A  to the interior rearview mirror -1-.

Fig 1: Identifying Solar Panel Attached To Interior Rearview Mirror
GWWN27-10800Courtesy of AUDI OF AMERICA, LLC

-- Lay the bottom on the instrument panel -2-.

NOTE:

The :VAS6102A  must not touch the instrument panel completely. Only the bottom edge may be used for support. If it touches completely, the color of the instrument panel could change.

-- Pull the securing string together so that the :VAS6102A  is close to the windshield.

-- Connect the connector for the :VAS6102A  to the vehicle diagnostic connection. Connecting is the same as with Vehicle Diagnostic Tester.

-- Check the :VAS6102A  functionality. The green LED must come on.