Home >> Audi >> 2017 >> TT Quattro Base, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 54 (Charging System (Battery, Starter, Generator) & Cruise Control (2 Of 2) [Coupe]) >> 27 Starter, Generator And Cruise Control >> Battery, Charging >> Battery Charger :VAS5900 >> Battery Charger :VAS5900 SERVICE CHARGE

Battery Charger :VAS5900 SERVICE CHARGE

WARNING: This page is about a different variant/trim than selected.

Special tools and workshop equipment required 

WARNING:

Risk of injury. Follow all warning messages and safety precautions. Refer to WARNINGS AND SAFETY PRECAUTIONS .

CAUTION:

"Service charging" is not permitted for VW vehicles, because voltage surges can damage the on-board electronics.

The Battery -A- must always be disconnected from the vehicle electrical system when using the "service charge" mode.

WARNING:

Do not check or charge a Battery -A- when the visual indicator has >>no color or is bright yellow<<. Jump starting must not be used!

There is a risk of explosion during testing, charging or jump starting.

These Batteries -A- must be replaced.

CAUTION:

Always set the mode that corresponds to the Battery -A- during the charging process. Refer to the :VAS5900  Operating Instructions.

"Service Charging" is suitable for:

  • Wet batteries having a visual indicator which allows charging (visual indicator black or green).

The "Service charge (SERV)" mode is only used with sulfated Batteries -A-. The Battery -A- with voltages greater than 14.4 V is charged. A partial removal of the sulfation layer can result from this. Check the visual indicator after charging, immediately before the Battery -A- is used. Refer to VISUAL INDICATOR COLOR DISPLAY, CHECKING .

NOTE:

The Battery -A- temperature must be at least 10 °C (50 °F).

Procedure 

-- Turn off the ignition and all electrical consumers and remove the ignition key.

-- Connect the :VAS5900  to the power supply. The last selected mode is shown on the display. Refer to Battery Charger .

-- Set the battery type with the INFO  button.

Fig 1: Identifying Battery Type Symbols
GWWN27-10179Courtesy of AUDI OF AMERICA, LLC

The symbol -1- for "service charge of wet batteries" or the symbol -2- for "service charge of Gel/Absorbent Glass Mat (AGM) batteries" is indicated in the display.

-- Set the battery capacity (Ah) on the Battery -A- to be charged with the corresponding ↑  button or ↓  button.

-- Connect the red charge terminal (+) to the positive terminal of the Battery -A-.

NOTE:

On vehicles with a Start/Stop function and an installed Battery Monitoring Control Module -J367-, the black charge terminal (-) must be connected to the body ground. The Start/Stop system will malfunction when it is connected to the Battery -A- negative terminal.

-- Connect the black charge terminal (-) to the negative terminal of the Battery -A- /negative connector.

The :VAS5900  recognizes the nominal voltage of the connected Battery -A- (6 V/12 V/24 V) and begins the charging process automatically.

The :VAS5900  begins the "final charging" when the charge level is approximately 80 to 85 % of the battery voltage. The fourth bar is indicated on the display -1-. The Battery -A- is now ready to be used.

Fig 2: Charging Unit Display, Charge Condition Approx. 80 - 85 %
GWWN27-10170Courtesy of AUDI OF AMERICA, LLC
NOTE:

A successful "service charge" depends on the degree of sulfation on the Battery -A-.

Possible malfunctions and how they are handled

  1. Displayed voltage does not match the nominal voltage:

    -- Hold down the ↑  button or ↓  button until the charging process begins.

  2. Displayed battery voltage does not match the nominal voltage - the charging process has already begun:

    -- Press the START/STOP  button two times.

    -- Hold down the ↑  button or ↓  button until the charging process begins.

  3. The charger does not recognize a Battery -A-, when the battery voltage is less than 2 V:

    The display remains unchanged.

    The set operating mode and Ampere-hours (Ah) are displayed.

Battery -A- charging, ending

-- Press the START/STOP  -button.

-- Remove the charging clamps from the battery terminals.

-- Disconnect the :VAS5900  from the power.