LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2017 >> TT Quattro Base, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 47 (Lubrication [CNTC,CYFB] (1 Of 2) [Coupe]) >> 17 Lubrication >> Crankcase Ventilation >> Overview - Crankcase Ventilation

Overview - Crankcase Ventilation

WARNING: This page is about a different variant/trim than selected.
Fig 1: Crankcase Ventilation Exploded View
GWWA17-10771Courtesy of AUDI OF AMERICA, LLC
  1. Cylinder Head Cover
  2. Seal
    • Always replace after removing
  3. Hose
    • To the EVAP Canister Purge Regulator Valve 1 -N80-
  4. Oil Separator
  5. Seal
    • Always replace after removing
  6. Hose
    • For the crankcase ventilation
    • To the turbocharger
  7. Bolt
    • 4 Nm
    • Thread cutting
    • Position the bolt by hand and tighten it until it finds the old threads. Then tighten the bolt to the specification.
  8. Seal
    • Always replace after removing
  9. Bolt
    • Tightening Specifications and Sequence 
      • Rest of World version. Refer to Fig 2.
      • China market version. Refer to Fig 3.
    • Thread cutting
    • Position the bolt by hand and tighten it until it finds the old threads. Then tighten the bolt to the specification.

Oil Separator - Tightening Specification and Sequence, Rest of World Version

Fig 2: Oil Separator - Tightening Sequence
GWWA17-11178Courtesy of AUDI OF AMERICA, LLC

-- Tighten the bolts to 9 Nm in the following sequence: -1 to 7-.

Oil Separator - Tightening Specification and Sequence, China Market Version

Fig 3: Oil Separator - Tightening Specification and Sequence (China Market Version)
GWWA17-11179Courtesy of AUDI OF AMERICA, LLC

-- Tighten the bolts to 9 Nm in the following sequence: -1 to 7-.