LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2017 >> TT Quattro Base, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 26 (Air Conditioning (Refrigerant R1234YF Servicing) (2 Of 2) [Coupe]) >> 87 Air Conditioning >> Working With A/C Service Station >> Contaminated Refrigerant, Filling In Recycling Container For Analysis, Processing, Or Disposal >> RECYCLING CONTAINER, FILLING WITH CONTAMINATED REFRIGERANT USING Extraction Unit:VAS581011

RECYCLING CONTAINER, FILLING WITH CONTAMINATED REFRIGERANT USING Extraction Unit:VAS581011

WARNING: This page is about a different variant/trim than selected.

Special tools and workshop equipment required 

Procedure 

-- Connect the Extraction Unit :VAS581011  according to the included Owner's Manual with the vehicle and the A/C Service Station R1234yf.

-- Fill the contaminated refrigerant using the Extraction Unit :VAS581011  in the recycling container. Refer to the Owner's Manual.

-- Fill out the supplement data sheet for the recycling bottle with contaminated refrigerant and secure on the recycling bottle.

-- Return the filled recycling bottle using the method of delivery for the recycling bottle, while paying attention to the applicable laws.

-- Evacuate the refrigerant circuit with the A/C Service Station for at least one hour. Refer to REFRIGERANT CIRCUIT, EVACUATING .