Home >> Audi >> 2017 >> TT Quattro Base, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 25 (Air Conditioning (Refrigerant R134A Servicing) (1 Of 2) [Coupe]) >> 87 Air Conditioning >> Refrigerant Circuit >> Refrigerant Circuit, Determining Leaks >> Leak Detection On Refrigerant Circuit Using Leak Detection Kit:Vas6201A >> Adding UV-Leak Detection Additive when the Refrigerant Circuit is Empty

Adding UV-Leak Detection Additive when the Refrigerant Circuit is Empty

WARNING: This page is about a different variant/trim than selected.
Fig 1: Identifying Cartridge & One Unit
GWWA87-0490Courtesy of AUDI OF AMERICA, LLC

The cartridge -A- contains 15.4 ml of UV-leak detection additive (one unit -B- corresponds to 2.5 ml).

-- Assemble the Leak Detection Kit :VAS6201A  -1- with the cartridge -2- Leak Detection Kit - Cartridge :VAS6201/2  .

Fig 2: Assembling Hand Pump VAS 6201 With Cartridge - VAS 6201/2
GWWA87-0496Courtesy of AUDI OF AMERICA, LLC

-- Insert the Leak Detection Kit - Filler Tube :VAS6201/8  . Refer to Add UV-Leak Detection Additive using the in the Refrigerant Circuit - Leak Detection Kit - Filler Tube:VAS6201/8  -item 7- into the hand pump.

-- Open the hand pump service valve.

NOTE:

UV-Leak detection additive is best added to the empty refrigerant circuit via a service connection or an opened connection.

If the refrigerant circuit is empty, then it is better to add the UV-leak detection additive via a connection point (for example, when the connection point is already open). This way no UV-leak detection additive remains in the service connection and the connection does not need to cleaned.