LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2017 >> TT Quattro Base, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 25 (Air Conditioning (Refrigerant R134A Servicing) (1 Of 2) [Coupe]) >> 87 Air Conditioning >> A/C System, General Information >> Refrigerant R134A >> Refrigerant R134A Physical Data

Refrigerant R134A Physical Data

WARNING: This page is about a different variant/trim than selected.

Vehicle air conditioning systems make use of the vaporization and condensation process. In this case, one works with a substance which boils easily, designated as refrigerant.

The refrigerant used is tetrafluoroethane R134a, which boils at -26.5 °C (-15.7 °F) at a vapor pressure of "1 bar (14.5 psi)" (absolute pressure corresponds slightly to the ambient pressure).

Chemical formula CH2F-CF3 or CF3-CH2F
Chemical designation Tetrafluoroethane
Boiling point at 1.0 bar (14.5 psi) 26.5 °C (79.7 °F)
Solidification point 101.6 °C (214.88 °F)
Critical temperature 100.6 °C (213.08 °F)
Critical pressure 40.56 bar (588.27 psi)