Service Connections On Low And High Pressure Side, Removing And Installing: Notes
WARNING: This page is about a different variant/trim than selected.
Special tools and workshop equipment required
- Refrigerant Sockets :T10364
WARNING:
Danger due to refrigerant coming out under pressure.
Danger of frost bite to skin and other parts of the body.
- Evacuate the refrigerant and immediately open the refrigerant circuit afterward.
- If more than 10 minutes have elapsed since evacuating the refrigerant and the refrigerant circuit was not opened, evacuate the refrigerant again. Pressure in the refrigerant circuit is caused by evaporation.
NOTE:
Certain tools are required to discharge the refrigerant circuit. These work procedures may only be performed by trained personnel. Refer to Refrigerant Circuit (Refrigerant R134a Servicing, Refrigerant Circuit, Working with A/C Service Station) and LAWS AND REGULATIONS .
There are different versions depending on the refrigerant (R134a or R1234yf). Refer to SERVICE CONNECTION DIFFERENCES, DEPENDING ON REFRIGERANT (R134A OR R1234YF) or Parts Information.